SI7055-A20-IM

SI7055-A20-IM


Specifications
Details

BUY SI7055-A20-IM https://www.utsource.net/itm/p/12608740.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating 1.9 3.6 V
Operating Temperature TA -40 85 掳C
Measurement Temperature Range TM RH = 10% to 80% -40 85 掳C
Relative Humidity Range RH TM = -40掳C to +65掳C 0 80 %RH
Conversion Time Tconv Typical 12 ms
Current Consumption IDD Active 370 渭A
IDD Sleep 0.05 渭A
Output Impedance Zout 20 k惟

Instructions for SI7055-A20-IM

  1. Power Supply Requirements:

    • Ensure the supply voltage (VDD) is within the range of 1.9V to 3.6V.
  2. Operating Environment:

    • The sensor operates effectively between temperatures of -40掳C to 85掳C.
    • For accurate humidity readings, ensure relative humidity is between 0% and 80%.
  3. Measurement Timing:

    • Allow a typical conversion time of 12ms for each measurement cycle.
  4. Power Management:

    • When not in use, place the device in sleep mode to reduce current consumption to approximately 0.05渭A.
  5. Signal Integrity:

    • Consider the output impedance of 20k惟 when integrating with other circuit components to avoid loading effects.
  6. Installation and Handling:

    • Handle with care to avoid damage from electrostatic discharge (ESD).

For detailed application notes and further specifications, refer to the official datasheet provided by the manufacturer.

(For reference only)

View more about SI7055-A20-IM on main site