Details
BUY 2SK902 https://www.utsource.net/itm/p/12608807.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | Vds | -50 | 50 | V | ||
| Gate-Source Voltage | Vgs | -10 | 10 | V | ||
| Continuous Drain Current | Id | 0.5 | 1 | A | Tc = 25掳C | |
| Pulsed Drain Current | Idp | 1.5 | 2 | A | t = 10 渭s, Duty = 1% | |
| Power Dissipation | Pd | 30 | W | Tc = 25掳C | ||
| Transconductance | Gfs | 0.4 | 0.6 | 0.8 | S | Vds = 25V, Vgs = 4V, Id = 0.5A |
| Input Capacitance | Ciss | 450 | pF | Vds = 0V, f = 1 MHz | ||
| Output Capacitance | Coss | 12 | pF | Vds = 25V, f = 1 MHz | ||
| Reverse Transfer Capacitance | Crss | 15 | pF | Vds = 25V, f = 1 MHz | ||
| Turn-On Delay Time | td(on) | 25 | 50 | ns | Vgs = 4V, Id = 0.5A, Vds = 25V | |
| Rise Time | tr | 15 | 30 | ns | Vgs = 4V, Id = 0.5A, Vds = 25V | |
| Turn-Off Delay Time | td(off) | 25 | 50 | ns | Vgs = 0V, Id = 0.5A, Vds = 25V | |
| Fall Time | tf | 15 | 30 | ns | Vgs = 0V, Id = 0.5A, Vds = 25V |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical damage.
- Use appropriate heat sinks to manage the power dissipation, especially when operating at high currents.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Apply the gate-source voltage (Vgs) within the specified range to control the device.
Operating Conditions:
- Do not exceed the maximum ratings for drain-source voltage (Vds), gate-source voltage (Vgs), and continuous drain current (Id).
- For pulsed applications, ensure that the pulse width and duty cycle are within the specified limits to avoid overheating.
Thermal Management:
- The device should be mounted on a suitable heatsink to maintain the junction temperature within safe limits.
- Monitor the temperature of the heatsink to ensure it does not exceed the maximum allowable temperature.
Storage and Transportation:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Use anti-static packaging to protect the device during transportation and storage.
Testing and Troubleshooting:
- Use a multimeter or an oscilloscope to verify the electrical parameters and performance of the device.
- If the device fails to operate as expected, check the connections, power supply, and any external components for faults.
Safety Precautions:
- Always disconnect the power supply before making any connections or changes to the circuit.
- Use appropriate personal protective equipment (PPE) when handling high-voltage circuits.