2SK902

2SK902


Specifications
SKU
12608807
Details

BUY 2SK902 https://www.utsource.net/itm/p/12608807.html

Parameter Symbol Min Typ Max Unit Conditions
Drain-Source Voltage Vds -50 50 V
Gate-Source Voltage Vgs -10 10 V
Continuous Drain Current Id 0.5 1 A Tc = 25掳C
Pulsed Drain Current Idp 1.5 2 A t = 10 渭s, Duty = 1%
Power Dissipation Pd 30 W Tc = 25掳C
Transconductance Gfs 0.4 0.6 0.8 S Vds = 25V, Vgs = 4V, Id = 0.5A
Input Capacitance Ciss 450 pF Vds = 0V, f = 1 MHz
Output Capacitance Coss 12 pF Vds = 25V, f = 1 MHz
Reverse Transfer Capacitance Crss 15 pF Vds = 25V, f = 1 MHz
Turn-On Delay Time td(on) 25 50 ns Vgs = 4V, Id = 0.5A, Vds = 25V
Rise Time tr 15 30 ns Vgs = 4V, Id = 0.5A, Vds = 25V
Turn-Off Delay Time td(off) 25 50 ns Vgs = 0V, Id = 0.5A, Vds = 25V
Fall Time tf 15 30 ns Vgs = 0V, Id = 0.5A, Vds = 25V

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is handled with care to avoid mechanical damage.
    • Use appropriate heat sinks to manage the power dissipation, especially when operating at high currents.
  2. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals correctly.
    • Apply the gate-source voltage (Vgs) within the specified range to control the device.
  3. Operating Conditions:

    • Do not exceed the maximum ratings for drain-source voltage (Vds), gate-source voltage (Vgs), and continuous drain current (Id).
    • For pulsed applications, ensure that the pulse width and duty cycle are within the specified limits to avoid overheating.
  4. Thermal Management:

    • The device should be mounted on a suitable heatsink to maintain the junction temperature within safe limits.
    • Monitor the temperature of the heatsink to ensure it does not exceed the maximum allowable temperature.
  5. Storage and Transportation:

    • Store the device in a dry, cool place away from direct sunlight and sources of heat.
    • Use anti-static packaging to protect the device during transportation and storage.
  6. Testing and Troubleshooting:

    • Use a multimeter or an oscilloscope to verify the electrical parameters and performance of the device.
    • If the device fails to operate as expected, check the connections, power supply, and any external components for faults.
  7. Safety Precautions:

    • Always disconnect the power supply before making any connections or changes to the circuit.
    • Use appropriate personal protective equipment (PPE) when handling high-voltage circuits.