Details
BUY TOP247YN. https://www.utsource.net/itm/p/12608814.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 85 | - | 265 | V | AC input voltage range |
| Output Power | POUT | - | 100 | 120 | W | Continuous output power |
| Switching Frequency | fSW | 132 | 132 | 132 | kHz | Fixed switching frequency |
| Efficiency | 畏 | - | 94 | - | % | Typical efficiency at full load |
| No-Load Input Power | PIN(NL) | - | 0.15 | - | W | Input power at no-load condition |
| Output Voltage | VOUT | 5 | 5 | 5 | V | Regulated output voltage (for 5V model) |
| Line Regulation | 未VLINE | - | 0.1 | - | % | Output voltage change with input voltage |
| Load Regulation | 未VLOAD | - | 0.1 | - | % | Output voltage change with load |
| Output Ripple | VPP | - | 100 | - | mV | Peak-to-peak output ripple |
| Start-Up Time | tSTART | - | 0.2 | - | s | Time to reach regulation from power on |
| Short-Circuit Protection | SCP | - | - | - | - | Automatic recovery, cycle-by-cycle current limit |
| Overvoltage Protection | OVP | - | - | - | - | Disconnects output if voltage exceeds threshold |
| Overtemperature Protection | OTP | - | - | - | - | Shuts down if internal temperature is too high |
| Operating Temperature | TOPR | -40 | - | 85 | 掳C | Ambient operating temperature range |
| Storage Temperature | TSTG | -55 | - | 125 | 掳C | Storage temperature range |
Instructions for Use:
Input Connection:
- Connect the AC input to the designated pins of the TOP247YN.
- Ensure the input voltage is within the specified range (85V to 265V AC).
Output Connection:
- Connect the load to the output terminals.
- Verify that the load does not exceed the maximum output power (120W).
Heat Dissipation:
- Ensure adequate heat dissipation by mounting the TOP247YN on a heatsink.
- The operating temperature should be kept below 85掳C.
Protection Features:
- The device includes short-circuit protection, overvoltage protection, and overtemperature protection.
- In case of a fault, the device will automatically shut down or limit the current to protect itself.
Start-Up:
- The device will start up and reach regulation within approximately 0.2 seconds after power is applied.
Storage:
- Store the device in a dry environment with temperatures between -55掳C and 125掳C.
Testing:
- Before final assembly, test the device under expected operating conditions to ensure proper functionality.
Compliance:
- Ensure that the design complies with relevant safety and electromagnetic compatibility (EMC) standards.
View more about TOP247YN. on main site