Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 85 - 265 V AC input voltage range
Output Power POUT - 100 120 W Continuous output power
Switching Frequency fSW 132 132 132 kHz Fixed switching frequency
Efficiency - 94 - % Typical efficiency at full load
No-Load Input Power PIN(NL) - 0.15 - W Input power at no-load condition
Output Voltage VOUT 5 5 5 V Regulated output voltage (for 5V model)
Line Regulation 未VLINE - 0.1 - % Output voltage change with input voltage
Load Regulation 未VLOAD - 0.1 - % Output voltage change with load
Output Ripple VPP - 100 - mV Peak-to-peak output ripple
Start-Up Time tSTART - 0.2 - s Time to reach regulation from power on
Short-Circuit Protection SCP - - - - Automatic recovery, cycle-by-cycle current limit
Overvoltage Protection OVP - - - - Disconnects output if voltage exceeds threshold
Overtemperature Protection OTP - - - - Shuts down if internal temperature is too high
Operating Temperature TOPR -40 - 85 掳C Ambient operating temperature range
Storage Temperature TSTG -55 - 125 掳C Storage temperature range

Instructions for Use:

  1. Input Connection:

    • Connect the AC input to the designated pins of the TOP247YN.
    • Ensure the input voltage is within the specified range (85V to 265V AC).
  2. Output Connection:

    • Connect the load to the output terminals.
    • Verify that the load does not exceed the maximum output power (120W).
  3. Heat Dissipation:

    • Ensure adequate heat dissipation by mounting the TOP247YN on a heatsink.
    • The operating temperature should be kept below 85掳C.
  4. Protection Features:

    • The device includes short-circuit protection, overvoltage protection, and overtemperature protection.
    • In case of a fault, the device will automatically shut down or limit the current to protect itself.
  5. Start-Up:

    • The device will start up and reach regulation within approximately 0.2 seconds after power is applied.
  6. Storage:

    • Store the device in a dry environment with temperatures between -55掳C and 125掳C.
  7. Testing:

    • Before final assembly, test the device under expected operating conditions to ensure proper functionality.
  8. Compliance:

    • Ensure that the design complies with relevant safety and electromagnetic compatibility (EMC) standards.