LVC139A

LVC139A


Specifications
SKU
12608888
Details

BUY LVC139A https://www.utsource.net/itm/p/12608888.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC 1.65 3.6 V
Input Voltage (High) VIH 0.7 × VCC VCC V
Input Voltage (Low) VIL 0 0.3 × VCC V
Output Voltage (High) VOH IOL = -4 mA 0.88 × VCC VCC V
Output Voltage (Low) VOL IOL = 4 mA 0 0.24 V
Propagation Delay Time tpd VCC = 3.3V, TA = 25°C 5 10 ns
Power Dissipation PD Continuous Operation 330 mW
Operating Temperature TA -40 85 °C
Storage Temperature TSTG -65 150 °C

Instructions for Using LVC139A

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 1.65V to 3.6V.
    • Connect VCC to the positive power supply and GND to the ground.
  2. Input Signals:

    • For a logic high input, the voltage should be at least 0.7 × VCC.
    • For a logic low input, the voltage should be no more than 0.3 × VCC.
  3. Output Signals:

    • The output voltage for a logic high will be at least 0.88 × VCC when sourcing up to 4 mA.
    • The output voltage for a logic low will be no more than 0.24V when sinking up to 4 mA.
  4. Propagation Delay:

    • The propagation delay time (tpd) is typically between 5 and 10 nanoseconds at 3.3V and 25°C.
  5. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -65°C to 150°C.
  6. Power Dissipation:

    • The maximum power dissipation is 330 mW under continuous operation.
  7. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store the device in a dry, cool place within the specified storage temperature range.
  8. Testing:

    • Before integrating the LVC139A into your circuit, test it with a simple setup to ensure it meets the required specifications.
  9. Layout and PCB Design:

    • Use proper PCB layout techniques to minimize noise and ensure reliable operation.
    • Keep signal traces short and use decoupling capacitors close to the power pins.
  10. Compliance:

    • Ensure that your design complies with all relevant safety and regulatory standards.
(For reference only)

View more about LVC139A on main site