| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 1.65 | 3.6 | V | ||
| Input Voltage (High) | VIH | 0.7 × VCC | VCC | V | ||
| Input Voltage (Low) | VIL | 0 | 0.3 × VCC | V | ||
| Output Voltage (High) | VOH | IOL = -4 mA | 0.88 × VCC | VCC | V | |
| Output Voltage (Low) | VOL | IOL = 4 mA | 0 | 0.24 | V | |
| Propagation Delay Time | tpd | VCC = 3.3V, TA = 25°C | 5 | 10 | ns | |
| Power Dissipation | PD | Continuous Operation | 330 | mW | ||
| Operating Temperature | TA | -40 | 85 | °C | ||
| Storage Temperature | TSTG | -65 | 150 | °C |
Instructions for Using LVC139A
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 1.65V to 3.6V.
- Connect VCC to the positive power supply and GND to the ground.
Input Signals:
- For a logic high input, the voltage should be at least 0.7 × VCC.
- For a logic low input, the voltage should be no more than 0.3 × VCC.
Output Signals:
- The output voltage for a logic high will be at least 0.88 × VCC when sourcing up to 4 mA.
- The output voltage for a logic low will be no more than 0.24V when sinking up to 4 mA.
Propagation Delay:
- The propagation delay time (tpd) is typically between 5 and 10 nanoseconds at 3.3V and 25°C.
Temperature Considerations:
- The operating temperature range is from -40°C to 85°C.
- The storage temperature range is from -65°C to 150°C.
Power Dissipation:
- The maximum power dissipation is 330 mW under continuous operation.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store the device in a dry, cool place within the specified storage temperature range.
Testing:
- Before integrating the LVC139A into your circuit, test it with a simple setup to ensure it meets the required specifications.
Layout and PCB Design:
- Use proper PCB layout techniques to minimize noise and ensure reliable operation.
- Keep signal traces short and use decoupling capacitors close to the power pins.
Compliance:
- Ensure that your design complies with all relevant safety and regulatory standards.