Details
BUY HA1265A https://www.utsource.net/itm/p/12608920.html
| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage (Vcc) | Operating voltage range | 4.5 | - | 5.5 | V |
| Quiescent Current | Current consumption when no load is applied | - | 30 | - | mA |
| Output Current | Maximum continuous output current | - | 500 | 1000 | mA |
| Thermal Shutdown Temperature | Temperature at which the device will shut down to prevent damage | - | 150 | - | 掳C |
| Storage Temperature Range | Temperature range for storage | -40 | - | 125 | 掳C |
| Operating Temperature Range | Temperature range for operation | -25 | - | 85 | 掳C |
| Dropout Voltage | Voltage difference between input and output when fully loaded | - | 1.2 | - | V |
| Line Regulation | Change in output voltage due to change in input voltage | - | 0.01 | - | %/V |
| Load Regulation | Change in output voltage due to change in load current | - | 0.01 | - | %/mA |
Instructions for Use:
Supply Voltage:
- Ensure the supply voltage (Vcc) is within the range of 4.5V to 5.5V.
- Avoid exceeding these limits to prevent damage to the device.
Quiescent Current:
- The quiescent current is typically 30mA. This is the current consumed by the device when no load is applied.
Output Current:
- The device can provide a maximum continuous output current of up to 1000mA, with a typical value of 500mA.
- Ensure the load does not exceed this limit to avoid overheating or damage.
Thermal Shutdown:
- The device will automatically shut down if the temperature exceeds 150掳C to prevent thermal damage.
- Ensure adequate heat dissipation to keep the device within safe operating temperatures.
Temperature Ranges:
- Storage Temperature: Store the device in a temperature range of -40掳C to 125掳C.
- Operating Temperature: Operate the device within a temperature range of -25掳C to 85掳C.
Dropout Voltage:
- The dropout voltage is typically 1.2V. This is the minimum difference required between the input and output voltages to maintain regulation under full load conditions.
Line Regulation:
- The line regulation is 0.01% per volt. This indicates the stability of the output voltage in response to changes in input voltage.
Load Regulation:
- The load regulation is 0.01% per milliamp. This indicates the stability of the output voltage in response to changes in load current.
Additional Notes:
- Always use appropriate decoupling capacitors (e.g., 10渭F and 0.1渭F) near the input and output pins to ensure stable operation.
- For high current applications, consider using a heatsink to improve thermal performance.
- Refer to the datasheet for detailed information and specific application circuits.
View more about HA1265A on main site