Details
BUY FDC37C651QFP https://www.utsource.net/itm/p/12608995.html
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Operating Voltage | Vcc | 4.75 | 5.0 | 5.25 | V |
| Operating Temperature | Ta | -40 | - | 85 | 掳C |
| Storage Temperature | Tstg | -55 | - | 150 | 掳C |
| Supply Current (Active) | Icc | - | 100 | 150 | 渭A |
| Supply Current (Standby) | Iccs | - | 10 | 20 | 渭A |
| Output High Level | VOH | 4.0 | - | Vcc-0.4 | V |
| Output Low Level | VOL | 0 | - | 0.4 | V |
| Input High Level | VIH | 2.0 | - | Vcc | V |
| Input Low Level | VIL | 0 | - | 0.8 | V |
| Propagation Delay Time | tpd | 20 | - | 50 | ns |
| Power-On Reset Time | tPOR | 100 | - | 500 | ms |
Instructions for FDC37C651QFP
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 4.75V to 5.25V.
- Use a stable power source to avoid voltage fluctuations that could affect the operation of the device.
Temperature Considerations:
- Operate the device within the temperature range of -40掳C to 85掳C.
- Store the device in an environment with temperatures between -55掳C and 150掳C.
Current Consumption:
- The active supply current (Icc) typically ranges from 100渭A to 150渭A.
- The standby supply current (Iccs) typically ranges from 10渭A to 20渭A.
Output Levels:
- Ensure the output high level (VOH) is at least 4.0V and no more than Vcc - 0.4V.
- Ensure the output low level (VOL) is between 0V and 0.4V.
Input Levels:
- The input high level (VIH) should be at least 2.0V and can go up to Vcc.
- The input low level (VIL) should be between 0V and 0.8V.
Timing Parameters:
- The propagation delay time (tpd) should be between 20ns and 50ns.
- The power-on reset time (tPOR) should be between 100ms and 500ms.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store the device in a dry, cool place to prevent moisture damage.
Mounting and Soldering:
- Follow the recommended soldering profile to ensure proper mounting on the PCB.
- Avoid excessive heat during soldering to prevent damage to the device.
Testing:
- Perform initial testing under controlled conditions to verify the functionality of the device.
- Regularly check the operating parameters to ensure they remain within the specified limits.
Application Notes:
- Refer to the datasheet and application notes for specific usage guidelines and circuit design recommendations.
View more about FDC37C651QFP on main site