Details
BUY UCC2893DW https://www.utsource.net/itm/p/12609015.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage Range | VCC | 8.5 | - | 76 | V | Operating input voltage range |
| Start Supply Current | ISS | - | 120 | 140 | 渭A | Initial supply current |
| Operating Supply Current | ICC | - | 3.5 | 4.5 | mA | Operating supply current |
| Minimum On-Time | tON(min) | 300 | - | - | ns | Minimum on-time for the switch |
| Maximum Off-Time | tOFF(max) | - | 6.9 | - | 渭s | Maximum off-time for the switch |
| Frequency | fSW | - | 65 | 100 | kHz | Switching frequency |
| Duty Cycle Limit | DCL | - | 0.5 | - | Duty cycle limit | |
| Overcurrent Protection | OCP | - | - | - | A | Threshold for overcurrent protection (dependent on external components) |
| Thermal Shutdown Temperature | TSD | - | 160 | - | 掳C | Temperature at which thermal shutdown is initiated |
Instructions for UCC2893DW:
Power Supply Connection:
- Connect the VCC pin to a power source within the specified input voltage range (8.5V to 76V).
External Components Setup:
- Choose external components such as resistors and capacitors to set the switching frequency and duty cycle according to the application requirements.
- Ensure that the inductor and diode used in the flyback configuration are rated for the expected current and voltage levels.
Overcurrent Protection:
- Implement an overcurrent protection circuit using a sense resistor connected between the CS pin and ground. Adjust the resistor value based on the desired overcurrent threshold.
Thermal Management:
- Monitor the temperature of the device to prevent it from exceeding the thermal shutdown temperature (160掳C). Use heatsinks or spread out heat generation if necessary.
Start-Up Sequence:
- The controller will start operating once the VCC voltage reaches the minimum operating level. Ensure a stable power-up sequence to avoid erratic behavior during startup.
Testing and Validation:
- After assembling the circuit, perform testing under various load conditions to ensure stability and performance meet the design specifications.
- Validate the operation by measuring the output voltage and current, ensuring they remain within acceptable limits.
Safety Precautions:
- Always handle the device with care to avoid damage from electrostatic discharge (ESD).
- Follow proper grounding and isolation practices when working with high-voltage circuits.
View more about UCC2893DW on main site