Parameter Symbol Min Typ Max Unit Description
Supply Voltage VCC 4.75 5.0 5.25 V Operating supply voltage range
Supply Current (Active) ICC - 30 - mA Current consumption in active mode
Supply Current (Standby) ICCS - 0.1 - mA Current consumption in standby mode
Input Voltage Range VI 0 - 5.5 V Input voltage range for all inputs
Output Voltage High VOH 2.4 - VCC-0.4 V Output voltage when high
Output Voltage Low VOL 0 - 0.4 V Output voltage when low
Output Current (High) IOH - - 2.6 mA Maximum output current when high
Output Current (Low) IOL - - 24 mA Maximum output current when low
Propagation Delay Time tpd - 10 - ns Propagation delay time
Storage Temperature Range Tstg -65 - 150 掳C Temperature range for storage
Operating Temperature Range TA 0 - 70 掳C Ambient temperature range

Instructions for Using P82C215-A

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 4.75V to 5.25V.
    • Connect the VCC pin to a stable 5V power source and ground (GND) to the system ground.
  2. Input Signals:

    • Apply input signals to the input pins (VI) within the range of 0V to 5.5V.
    • Ensure that the input signals do not exceed the maximum input voltage to avoid damage.
  3. Output Signals:

    • The output pins will provide logic levels with VOH and VOL as specified.
    • The maximum output current when the output is high (IOH) is 2.6mA, and when the output is low (IOL) is 24mA. Ensure that the load does not exceed these limits.
  4. Propagation Delay:

    • The typical propagation delay time (tpd) is 10ns. This should be considered in timing-sensitive applications.
  5. Temperature Considerations:

    • Store the device in an environment with a temperature range of -65掳C to 150掳C.
    • Operate the device within an ambient temperature range of 0掳C to 70掳C to ensure reliable performance.
  6. Handling and Storage:

    • Handle the device with care to avoid static discharge and physical damage.
    • Store the device in a dry, cool place to prevent moisture-related issues.
  7. Testing:

    • Before integrating the device into a circuit, test it using a known good setup to verify its functionality.
    • Use appropriate test equipment to measure supply current, input/output voltages, and propagation delay.

By following these instructions, you can ensure optimal performance and reliability of the P82C215-A in your application.

(For reference only)