Details
BUY LM138K-MIL https://www.utsource.net/itm/p/12609048.html
| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Output Voltage | Adjustable output voltage range | 1.2 | - | 37 | V |
| Line Regulation | Change in output voltage with respect to line voltage | - | 0.015 | - | %/V |
| Load Regulation | Change in output voltage with respect to load current | - | 0.1 | - | %/mA |
| Dropout Voltage | Minimum input-to-output voltage difference required for regulation | - | 1.5 | - | V |
| Quiescent Current | Supply current when no load is applied | 10 | - | 40 | mA |
| Output Current | Maximum continuous output current | - | - | 1.5 | A |
| Thermal Shutdown | Temperature at which the device shuts down to prevent damage | - | - | 175 | 掳C |
| Storage Temperature | Range of temperatures over which the device can be stored without damage | -65 | - | 150 | 掳C |
| Operating Temperature | Range of temperatures over which the device can operate | -55 | - | 125 | 掳C |
Instructions for Using the LM138K-MIL
Circuit Configuration:
- The LM138K-MIL is an adjustable three-terminal positive voltage regulator.
- Connect the input voltage to the "IN" pin, the output voltage to the "OUT" pin, and the adjustment pin to a resistor network to set the desired output voltage.
Output Voltage Setting:
- Use the following formula to set the output voltage: [ V_{text} = 1.25 left(1 + fracright) + I_{text} R_2 ]
- Where ( V_{text} ) is the desired output voltage, ( R_1 ) and ( R_2 ) are the resistors in the feedback network, and ( I_{text} ) is the adjustment pin current (typically very small, around 50 渭A).
Capacitor Requirements:
- For stable operation, a minimum of 1 渭F tantalum capacitor should be connected between the output and ground.
- A 1 渭F tantalum capacitor should also be connected between the input and ground if the regulator is located more than 6 inches from the power supply filter.
Thermal Considerations:
- Ensure adequate heat sinking to keep the junction temperature below 175掳C.
- Calculate the power dissipation using the formula: [ P_d = (V_{text} - V_{text}) times I_{text} ]
- Use a heatsink if necessary to maintain safe operating temperatures.
Storage and Handling:
- Store the device in a dry, cool environment within the storage temperature range (-65掳C to 150掳C).
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
Operating Temperature:
- Operate the device within the specified operating temperature range (-55掳C to 125掳C) to ensure reliable performance.
Testing and Troubleshooting:
- Verify the output voltage with a multimeter to ensure it matches the desired setting.
- Check for proper connections and ensure all components are functioning correctly.
- If the device overheats or fails to regulate, check for short circuits or incorrect component values.
View more about LM138K-MIL on main site