Details
BUY MC1747CP2. https://www.utsource.net/itm/p/12609059.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Continuous Operation | 3.0 | - | 40 | V |
| Output Voltage Range | VOUT | Adjustable | 1.25 | - | 37 | V |
| Output Current | IOUT | Continuous | - | 1.5 | - | A |
| Quiescent Current | IQ | VOUT = 5V, IOUT = 0mA | - | 5 | - | mA |
| Dropout Voltage | VDROP | IOUT = 1.5A | - | 2.0 | - | V |
| Line Regulation | ΔVOUT/ΔVIN | 1.25V ≤ VOUT ≤ 37V, IOUT = 1.5A | - | 0.01 | - | %/V |
| Load Regulation | ΔVOUT/ΔIOUT | VOUT = 5V, 0mA ≤ IOUT ≤ 1.5A | - | 0.01 | - | %/A |
| Thermal Shutdown Temperature | TSD | - | - | 160 | - | °C |
| Operating Junction Temperature | TJ | - | -25 | - | 150 | °C |
Instructions for Use:
Input Voltage (VIN):
- Ensure the input voltage is within the range of 3.0V to 40V.
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Voltage (VOUT):
- The output voltage can be adjusted between 1.25V and 37V.
- Use the external resistors R1 and R2 to set the desired output voltage using the formula: VOUT = 1.25V * (1 + R1/R2).
Output Current (IOUT):
- The device can provide a continuous output current of up to 1.5A.
- Ensure the load does not exceed this limit to avoid overheating or damage.
Quiescent Current (IQ):
- The quiescent current is typically 5mA when no load is applied.
- This value helps in calculating the power consumption of the regulator when idle.
Dropout Voltage (VDROP):
- The dropout voltage is typically 2.0V at full load (1.5A).
- Ensure the input voltage is at least 2.0V higher than the output voltage to maintain regulation.
Line Regulation:
- The line regulation is 0.01% per volt, indicating minimal change in output voltage with changes in input voltage.
Load Regulation:
- The load regulation is 0.01% per amp, indicating minimal change in output voltage with changes in load current.
Thermal Shutdown:
- The device will automatically shut down if the junction temperature exceeds 160°C to prevent thermal damage.
- Ensure proper heat dissipation, especially under high load conditions.
Operating Junction Temperature:
- The operating junction temperature range is from -25°C to 150°C.
- Ensure the device operates within this temperature range to avoid performance degradation or failure.
Additional Notes:
- Always use appropriate decoupling capacitors on both the input and output sides to ensure stable operation.
- For high current applications, consider using a heatsink to improve thermal performance.
View more about MC1747CP2. on main site