MC1747CP2.

MC1747CP2.


Specifications
SKU
12609059
Details

BUY MC1747CP2. https://www.utsource.net/itm/p/12609059.html

Parameter Symbol Conditions Min Typ Max Unit
Input Voltage VIN Continuous Operation 3.0 - 40 V
Output Voltage Range VOUT Adjustable 1.25 - 37 V
Output Current IOUT Continuous - 1.5 - A
Quiescent Current IQ VOUT = 5V, IOUT = 0mA - 5 - mA
Dropout Voltage VDROP IOUT = 1.5A - 2.0 - V
Line Regulation ΔVOUT/ΔVIN 1.25V ≤ VOUT ≤ 37V, IOUT = 1.5A - 0.01 - %/V
Load Regulation ΔVOUT/ΔIOUT VOUT = 5V, 0mA ≤ IOUT ≤ 1.5A - 0.01 - %/A
Thermal Shutdown Temperature TSD - - 160 - °C
Operating Junction Temperature TJ - -25 - 150 °C

Instructions for Use:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the range of 3.0V to 40V.
    • Avoid exceeding the maximum input voltage to prevent damage to the device.
  2. Output Voltage (VOUT):

    • The output voltage can be adjusted between 1.25V and 37V.
    • Use the external resistors R1 and R2 to set the desired output voltage using the formula: VOUT = 1.25V * (1 + R1/R2).
  3. Output Current (IOUT):

    • The device can provide a continuous output current of up to 1.5A.
    • Ensure the load does not exceed this limit to avoid overheating or damage.
  4. Quiescent Current (IQ):

    • The quiescent current is typically 5mA when no load is applied.
    • This value helps in calculating the power consumption of the regulator when idle.
  5. Dropout Voltage (VDROP):

    • The dropout voltage is typically 2.0V at full load (1.5A).
    • Ensure the input voltage is at least 2.0V higher than the output voltage to maintain regulation.
  6. Line Regulation:

    • The line regulation is 0.01% per volt, indicating minimal change in output voltage with changes in input voltage.
  7. Load Regulation:

    • The load regulation is 0.01% per amp, indicating minimal change in output voltage with changes in load current.
  8. Thermal Shutdown:

    • The device will automatically shut down if the junction temperature exceeds 160°C to prevent thermal damage.
    • Ensure proper heat dissipation, especially under high load conditions.
  9. Operating Junction Temperature:

    • The operating junction temperature range is from -25°C to 150°C.
    • Ensure the device operates within this temperature range to avoid performance degradation or failure.

Additional Notes:

  • Always use appropriate decoupling capacitors on both the input and output sides to ensure stable operation.
  • For high current applications, consider using a heatsink to improve thermal performance.
(For reference only)

View more about MC1747CP2. on main site