Details
BUY GP1A52HRJ00F https://www.utsource.net/itm/p/12609145.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 2.8 | 5 | 5.5 | V |
| Supply Current | ICC | No load, VCC = 5V | - | 10 | - | mA |
| Output High Level Voltage | VOH | IL = 0mA, VCC = 5V | 4.2 | - | 5 | V |
| Output Low Level Voltage | VOL | IL = 20mA, VCC = 5V | 0 | - | 0.4 | V |
| Output Rise Time | tr | VCC = 5V, RL = 1k惟, CL = 20pF | - | 10 | - | 渭s |
| Output Fall Time | tf | VCC = 5V, RL = 1k惟, CL = 20pF | - | 10 | - | 渭s |
| Detection Distance | Dr | White Reflective Tape | 4 | - | 8 | mm |
Instructions for GP1A52HRJ00F
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.8V to 5.5V.
- The typical supply current (ICC) is 10mA at no load and VCC = 5V.
Output Levels:
- For the output high level voltage (VOH), ensure it operates between 4.2V and 5V when no load is present and VCC = 5V.
- For the output low level voltage (VOL), ensure it remains between 0V and 0.4V when a load current (IL) of 20mA is applied and VCC = 5V.
Timing Characteristics:
- The output rise time (tr) and fall time (tf) should typically be around 10渭s under conditions where VCC = 5V, RL = 1k惟, and CL = 20pF.
Detection Range:
- The detection distance (Dr) for white reflective tape should be between 4mm and 8mm for optimal performance.
Mounting and Handling:
- Carefully mount the sensor ensuring that the sensing surface is not obstructed or covered by non-reflective materials.
- Avoid exposing the sensor to excessive mechanical stress or moisture which can affect its performance.
Application Considerations:
- This sensor is suitable for applications requiring object detection, such as in automated machinery or robotics.
- Adjust the position of the sensor relative to the target based on the specified detection distance for reliable operation.