GP1A52HRJ00F

GP1A52HRJ00F


Specifications
Details

BUY GP1A52HRJ00F https://www.utsource.net/itm/p/12609145.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.8 5 5.5 V
Supply Current ICC No load, VCC = 5V - 10 - mA
Output High Level Voltage VOH IL = 0mA, VCC = 5V 4.2 - 5 V
Output Low Level Voltage VOL IL = 20mA, VCC = 5V 0 - 0.4 V
Output Rise Time tr VCC = 5V, RL = 1k惟, CL = 20pF - 10 - 渭s
Output Fall Time tf VCC = 5V, RL = 1k惟, CL = 20pF - 10 - 渭s
Detection Distance Dr White Reflective Tape 4 - 8 mm

Instructions for GP1A52HRJ00F

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.8V to 5.5V.
    • The typical supply current (ICC) is 10mA at no load and VCC = 5V.
  2. Output Levels:

    • For the output high level voltage (VOH), ensure it operates between 4.2V and 5V when no load is present and VCC = 5V.
    • For the output low level voltage (VOL), ensure it remains between 0V and 0.4V when a load current (IL) of 20mA is applied and VCC = 5V.
  3. Timing Characteristics:

    • The output rise time (tr) and fall time (tf) should typically be around 10渭s under conditions where VCC = 5V, RL = 1k惟, and CL = 20pF.
  4. Detection Range:

    • The detection distance (Dr) for white reflective tape should be between 4mm and 8mm for optimal performance.
  5. Mounting and Handling:

    • Carefully mount the sensor ensuring that the sensing surface is not obstructed or covered by non-reflective materials.
    • Avoid exposing the sensor to excessive mechanical stress or moisture which can affect its performance.
  6. Application Considerations:

    • This sensor is suitable for applications requiring object detection, such as in automated machinery or robotics.
    • Adjust the position of the sensor relative to the target based on the specified detection distance for reliable operation.
(For reference only)

View more about GP1A52HRJ00F on main site