Details
BUY F10P20F https://www.utsource.net/itm/p/12609184.html
| Parameter | Symbol | Min | Typical | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | Vin | 85 | - | 264 | V | AC Input Voltage Range |
| Output Voltage | Vout | 12 | - | 12 | V | DC Output Voltage |
| Output Current | Iout | - | 2.0 | 2.0 | A | Continuous Output Current |
| Efficiency | 畏 | - | 87 | 90 | % | Typical Efficiency at Full Load |
| Power Factor | PF | 0.9 | - | 1.0 | - | Power Factor at Full Load |
| No-Load Current | I NL | - | 0.01 | 0.03 | A | No-Load Input Current |
| Ripple & Noise | VRMS | - | 50 | 100 | mVp-p | Output Ripple and Noise |
| Operating Temp. | Toper | -40 | - | 85 | 掳C | Operating Temperature Range |
| Storage Temp. | Tstore | -40 | - | 85 | 掳C | Storage Temperature Range |
| Protection | - | - | - | - | - | Overvoltage, Overcurrent, Short-Circuit Protection |
Instructions for Use:
Input Connection:
- Connect the AC input to the F10P20F using the provided input terminals.
- Ensure the input voltage is within the specified range (85V to 264V AC).
Output Connection:
- Connect the DC output to your load using the output terminals.
- The output voltage is fixed at 12V DC with a maximum current of 2.0A.
Mounting:
- Mount the F10P20F in a well-ventilated area to ensure proper heat dissipation.
- Avoid placing it in direct sunlight or near heat sources.
Operation:
- Turn on the power supply by connecting it to the AC source.
- Monitor the output voltage and current to ensure they are within the specified limits.
Protection Features:
- The F10P20F includes overvoltage, overcurrent, and short-circuit protection.
- If any of these conditions occur, the power supply will shut down to prevent damage.
Maintenance:
- Regularly inspect the connections and terminals for signs of wear or damage.
- Clean the power supply with a dry cloth to remove dust and debris.
Storage:
- Store the F10P20F in a dry, cool place with temperatures between -40掳C and 85掳C.
Safety Precautions:
- Do not operate the power supply in environments with high humidity or corrosive gases.
- Always disconnect the power supply from the AC source before performing any maintenance or repairs.