Details
BUY PBYR1645 https://www.utsource.net/itm/p/12609277.html
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Forward Voltage | Vf | - | 1.8 | 2.2 | V |
| Reverse Breakdown Voltage | Vr | - | - | 5 | V |
| Continuous Forward Current | If | - | 30 | 50 | mA |
| Peak Forward Current (10 ms) | Ifsm | - | 100 | - | mA |
| Power Dissipation | Pd | - | - | 125 | mW |
| Operating Temperature | Topr | -40 | - | 85 | 掳C |
| Storage Temperature | Tstg | -40 | - | 100 | 掳C |
Instructions for Use:
- Mounting: Ensure that the component is mounted on a flat surface to avoid mechanical stress.
- Soldering: Use a soldering iron with a temperature not exceeding 300掳C and complete soldering within 5 seconds to prevent thermal damage.
- Electrical Connections: Connect the component according to the polarity indicated on the datasheet. The cathode (K) and anode (A) should be correctly identified.
- Heat Sinking: For applications where the component will operate near its maximum power dissipation, consider using a heat sink to improve thermal performance.
- Surge Currents: Avoid exposing the component to surge currents exceeding the peak forward current rating for extended periods.
- Environmental Conditions: Ensure that the operating and storage temperatures are within the specified ranges to maintain reliability.
- Handling: Handle the component with care to avoid static discharge, which can damage sensitive components. Use appropriate ESD protection measures.
View more about PBYR1645 on main site