Details
BUY MC74LVX4245DW https://www.utsource.net/itm/p/12609286.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 1.65 | 3.6 | V | ||
| Output High-Level Voltage | VOH | IO = -0.5 mA, VCC = 3.3 V | 3.3 | V | ||
| Output Low-Level Voltage | VOL | IO = 4.0 mA, VCC = 3.3 V | 0.2 | V | ||
| Input Leakage Current | IIL | VI = 0 to VCC, TA = 25掳C | -1 | 1 | 渭A | |
| Propagation Delay Time | tpd | VCC = 3.3 V, TA = 25掳C | 2.9 | ns | ||
| Power Consumption | ICC | VCC = 3.3 V, f = 0 Hz | 1 | 渭A |
Instructions for MC74LVX4245DW
Supply Voltage:
- Ensure the supply voltage (VCC) is within the range of 1.65V to 3.6V to prevent damage to the device.
Output Voltage Levels:
- The output high-level voltage (VOH) should not exceed the supply voltage.
- The output low-level voltage (VOL) should be as close to 0V as possible under load conditions.
Input Handling:
- Be cautious with input leakage current; ensure inputs are properly terminated or driven to avoid floating states which can lead to increased power consumption.
Propagation Delay:
- Account for propagation delay in timing calculations to ensure proper signal integrity and system performance.
Power Management:
- Monitor the power consumption especially at no-load conditions to optimize power efficiency.
Operating Temperature:
- Ensure the device operates within its specified temperature range to maintain reliability and performance.
Handling Precautions:
- Follow standard ESD handling procedures to protect the device from electrostatic discharge damage.
Installation:
- Ensure correct orientation during installation to prevent damage and ensure proper functionality.
View more about MC74LVX4245DW on main site