Specifications
Details

BUY D13009K https://www.utsource.net/itm/p/12609417.html

Parameter Symbol Conditions Min Typ Max Unit
Forward Voltage V_F IF = 20 mA 1.8 2.2 V
Reverse Current I_R VR = 5 V 100 渭A
Peak Inverse Voltage V_RM 5 V
Operating Temperature T_op -40 85 掳C
Storage Temperature T_stg -65 150 掳C

Instructions for D13009K

  1. Handling and Storage:

    • Store in a dry, cool place within the temperature range of -65掳C to 150掳C.
    • Handle with care to avoid physical damage.
  2. Mounting:

    • Ensure proper alignment during mounting to prevent damage to leads.
    • Follow manufacturer guidelines for soldering temperature and duration.
  3. Electrical Operation:

    • Do not exceed the peak inverse voltage (V_RM) of 5V to avoid breakdown.
    • Keep reverse current (I_R) below 100 渭A at 5V to ensure reliable operation.
  4. Environmental Considerations:

    • Operate within the specified temperature range (-40掳C to 85掳C) for optimal performance.
    • Protect from moisture and corrosive environments.
  5. Testing:

    • Verify forward voltage (V_F) is between 1.8V and 2.2V at a forward current (IF) of 20 mA during testing.

For detailed specifications and additional information, refer to the official datasheet provided by the manufacturer.