| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Forward Current | IF | - | - | 50 | mA | Continuous |
| Peak Forward Current | IF(P) | - | - | 150 | mA | Pulse (10% duty cycle, 100 Hz) |
| Reverse Voltage | VR | - | - | 5 | V | |
| Forward Voltage | VF | 1.8 | 2.2 | 2.6 | V | IF = 20 mA |
| Reverse Current | IR | - | - | 100 | nA | VR = 5 V |
| Luminous Intensity | Iv | 2 | 4.5 | 7 | mcd | IF = 20 mA |
| Viewing Angle | 胃 | - | 30掳 | - | 掳 | |
| Operating Temperature | Toper | -40 | - | 85 | 掳C | |
| Storage Temperature | Tstg | -40 | - | 100 | 掳C |
Instructions for Use:
Mounting:
- Ensure that the leads are not bent at sharp angles to avoid mechanical stress.
- Soldering temperature should not exceed 260掳C for more than 10 seconds.
Electrical Connections:
- Connect the longer lead (anode) to the positive terminal of the power supply.
- Connect the shorter lead (cathode) to the negative terminal or ground.
Current Limiting:
- Use a current-limiting resistor to ensure the forward current does not exceed 50 mA continuously.
- For pulse applications, do not exceed 150 mA with a 10% duty cycle at 100 Hz.
Heat Dissipation:
- If operating at high currents, ensure adequate heat dissipation to prevent overheating.
- Avoid prolonged exposure to temperatures above 85掳C.
Storage:
- Store in a dry place away from direct sunlight.
- Ensure storage temperature is between -40掳C and 100掳C.
Handling:
- Handle with care to avoid damaging the leads or the body of the component.
- Use anti-static precautions to prevent damage from electrostatic discharge.
Testing:
- Test the component using a multimeter set to measure diode or continuity to ensure proper functionality.
- Verify the forward voltage and luminous intensity under specified conditions.