ACPL-M61L

ACPL-M61L


Specifications
Details

BUY ACPL-M61L https://www.utsource.net/itm/p/12609515.html

Parameter Symbol Conditions Min Typ Max Unit
Input Forward Voltage V_F IF = 20 mA 1.1 1.3 1.5 V
Reverse Breakdown Voltage V_BR IR = 1 mA 5 - 7 V
Output Collector-Emitter Saturation Voltage V_CE(sat) IC = 15 mA, V_CE(sat) ≤ 0.5 V - 0.2 0.4 V
Output Collector Leakage Current I_CBO VR = 5 V - 10 100 nA
Isolation Voltage V_IORM 1 minute, 50/60 Hz - - 5000 Vrms
Propagation Delay Time t_pl V_IN = 5 V, RL = 100 Ω 2 4 6 μs
Rise Time t_r V_IN = 5 V, RL = 100 Ω 0.1 0.3 0.5 μs
Fall Time t_f V_IN = 5 V, RL = 100 Ω 0.1 0.3 0.5 μs

Instructions for ACPL-M61L

  1. Installation and Handling:

    • Handle the device with care to avoid damage.
    • Ensure proper alignment during installation to prevent short circuits.
  2. Power Supply:

    • Ensure that the input voltage is within the specified range to avoid damaging the component.
    • Use appropriate decoupling capacitors near the power supply pins to minimize noise.
  3. Operating Temperature Range:

    • The device operates reliably within the temperature range of -40°C to +85°C.
  4. Input Circuit:

    • Connect a current-limiting resistor in series with the LED input to ensure the forward current does not exceed the maximum rating.
  5. Output Circuit:

    • Ensure the collector-emitter voltage (V_CE) does not exceed the rated breakdown voltage.
    • Connect a pull-down resistor between the output and ground to ensure stable operation when the output is off.
  6. Electrical Isolation:

    • The device provides electrical isolation up to 5000 Vrms for one minute at 50/60 Hz. Ensure this isolation capability meets your application requirements.
  7. Signal Timing:

    • Consider the propagation delay, rise time, and fall time in timing-sensitive applications to ensure reliable performance.
  8. Storage:

    • Store in a dry, cool place away from direct sunlight and corrosive materials.
  9. Mounting:

    • Follow the manufacturer’s guidelines for PCB layout and mounting to ensure optimal thermal performance and mechanical stability.
  10. Safety Precautions:

    • Always follow safety guidelines when handling high voltages and currents.
    • Ensure proper grounding and insulation to protect against electrical hazards.
(For reference only)