Details
BUY SN75176BN https://www.utsource.net/itm/p/12609554.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.75 | 5 | 5.25 | V | |
| Output High-Level Voltage | VOH | 2.4 | 3.4 | V | @ IOH = -4mA, VCC = 5V | |
| Output Low-Level Voltage | VOL | 0.1 | 0.4 | V | @ IOL = 16mA, VCC = 5V | |
| Input High-Level Voltage | VIH | 2 | 3.5 | 5.25 | V | |
| Input Low-Level Voltage | VIL | 0 | 0.8 | 1.5 | V | |
| Differential Input Impedance | ZDIFF | 75 | 惟 | @ f = 20MHz | ||
| Common-Mode Input Impedance | ZCM | 5 | k惟 | @ f = 20MHz | ||
| Driver Output Current | IOL | 16 | 20 | mA | @ VOL = 0.4V, VCC = 5V | |
| Driver Output Current | IOH | -20 | -16 | mA | @ VOH = 2.4V, VCC = 5V | |
| Maximum Data Rate | 2.5 | Mbps | ||||
| Operating Temperature Range | Toper | -40 | 85 | 掳C | ||
| Storage Temperature Range | Tstg | -65 | 150 | 掳C |
Instructions for Using the SN75176BN
Power Supply:
- Ensure that the supply voltage (VCC) is within the specified range of 4.75V to 5.25V.
- Connect the ground (GND) pin to a stable ground reference.
Signal Lines:
- Connect the differential input pins (RIN+ and RIN-) to the differential signals you wish to transmit or receive.
- Connect the differential output pins (TOUT+ and TOUT-) to the differential lines of the communication channel.
Control Signals:
- DE (Driver Enable): Set to high to enable the driver section for transmission.
- RE (Receiver Enable): Set to low to enable the receiver section for reception.
- When both DE and RE are high, the device is in a high-impedance state (tristate).
Data Rate:
- The maximum data rate supported by the SN75176BN is 2.5 Mbps. Ensure that your application does not exceed this limit to avoid signal integrity issues.
Temperature Considerations:
- The operating temperature range is -40掳C to 85掳C. Ensure that the device is used within this range to maintain reliable operation.
- The storage temperature range is -65掳C to 150掳C. Store the device in a suitable environment to prevent damage.
Termination:
- For optimal performance, terminate the differential lines with a 120惟 resistor at both ends of the transmission line.
Electrostatic Discharge (ESD) Protection:
- Handle the device with care to avoid ESD damage. Use appropriate ESD protection measures when handling and installing the device.
Layout Considerations:
- Keep the signal traces as short as possible to minimize reflections and crosstalk.
- Use a ground plane to reduce noise and improve signal integrity.
By following these instructions, you can ensure that the SN75176BN operates reliably and efficiently in your application.
(For reference only)View more about SN75176BN on main site