| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.0 | - | 5.5 | V | |
| Output Current (High) | IOH | - | - | 25 | mA | VCC = 5V |
| Output Current (Low) | IOL | - | - | 50 | mA | VCC = 5V |
| Input Voltage (High) | VIH | 2.0 | - | 5.5 | V | |
| Input Voltage (Low) | VIL | 0.0 | - | 0.8 | V | |
| Propagation Delay Time | tpd | - | 25 | 50 | ns | VCC = 5V, TA = 25掳C |
| Power Dissipation | PD | - | - | 340 | mW | TA = 70掳C |
| Operating Temperature | TA | -40 | - | 85 | 掳C | |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C |
Instructions for Use
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 2.0V to 5.5V to avoid damage to the device.
Output Current:
- The maximum output current for high and low states should not exceed 25mA and 50mA, respectively, when VCC is 5V.
Input Voltage Levels:
- For proper operation, input voltages should be within the specified ranges:
- High level (VIH): 2.0V to 5.5V
- Low level (VIL): 0.0V to 0.8V
- For proper operation, input voltages should be within the specified ranges:
Propagation Delay Time:
- The typical propagation delay time is 25ns, with a maximum of 50ns at VCC = 5V and ambient temperature (TA) = 25掳C.
Power Dissipation:
- The maximum power dissipation is 340mW at an ambient temperature of 70掳C. Ensure adequate heat dissipation if operating near this limit.
Operating and Storage Temperature:
- The device can operate within a temperature range of -40掳C to 85掳C and can be stored between -65掳C and 150掳C.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Ensure all connections are secure and free from shorts or open circuits.
Mounting and Soldering:
- Follow recommended soldering profiles to avoid thermal stress on the device.
- Use appropriate flux and cleaning agents to ensure reliable connections.
Testing:
- Perform initial testing under controlled conditions to verify correct operation before integrating into a larger system.
Compliance:
- Ensure the device complies with relevant safety and regulatory standards for your application.