AD586KRZ

AD586KRZ


Specifications
SKU
12609605
Details

BUY AD586KRZ https://www.utsource.net/itm/p/12609605.html

Below is the parameter table and instructions for the AD586KRZ, which is a precision 2.5V voltage reference from Analog Devices.

AD586KRZ Parameter Table

Parameter Symbol Min Typ Max Unit Conditions
Output Voltage VOUT - 2.500 - V 0°C to +70°C
Initial Accuracy ΔVOUT(25°C) -0.1 0.0 +0.1 % @ 25°C
Temperature Coefficient TC -10 5 +10 ppm/°C 0°C to +70°C
Line Regulation ΔVOUT/ΔVIN - 0.5 - ppm/V 4.5V ≤ VIN ≤ 30V
Load Regulation ΔVOUT/ΔIL - 10 - ppm/mA IL = 0mA to 10mA
Supply Current IS - 1.0 - mA VIN = 5V
Dropout Voltage VDROP - 0.2 - V IL = 10mA
Operating Temperature Range TA -40 - +85 °C -
Storage Temperature Range TSTG -65 - +150 °C -

Instructions for Use

  1. Power Supply:

    • The AD586KRZ operates with a supply voltage (VIN) ranging from 4.5V to 30V.
    • Ensure that the supply voltage is stable and within the specified range to avoid damage or performance degradation.
  2. Output Voltage:

    • The output voltage (VOUT) is nominally 2.5V.
    • For best accuracy, use a low-impedance load and ensure that the load current (IL) is within the specified range (0mA to 10mA).
  3. Temperature Considerations:

    • The initial accuracy and temperature coefficient are critical parameters for maintaining precision over temperature.
    • For applications requiring high precision, consider using temperature compensation techniques or operating the device within a controlled temperature environment.
  4. Load Regulation:

    • The load regulation is specified as 10 ppm/mA. This means that changes in load current can affect the output voltage.
    • To minimize load regulation effects, use a buffer amplifier between the AD586KRZ and the load.
  5. Line Regulation:

    • The line regulation is specified as 0.5 ppm/V. This indicates how much the output voltage changes with variations in the input voltage.
    • Use a stable power supply to minimize line regulation effects.
  6. Dropout Voltage:

    • The dropout voltage is the minimum difference between the input and output voltages required for the device to maintain regulation.
    • Ensure that the input voltage is at least 0.2V higher than the output voltage to avoid dropout.
  7. Operating and Storage Temperature:

    • The device is designed to operate over a wide temperature range (-40°C to +85°C).
    • Store the device in a dry environment within the storage temperature range (-65°C to +150°C) to prevent damage.
  8. PCB Layout:

    • Use a ground plane to minimize noise and improve thermal performance.
    • Place decoupling capacitors close to the power pins to reduce supply noise.
  9. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal circuitry.
    • Follow proper ESD (Electrostatic Discharge) precautions during handling and installation.

By following these instructions, you can ensure optimal performance and reliability of the AD586KRZ in your application.

(For reference only)

View more about AD586KRZ on main site