| Parameter | Symbol | Min | Typical | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | V_IN | 2.7 | - | 5.5 | V | Operating input voltage range |
| Output Voltage | V_OUT | - | 3.3 | - | V | Fixed output voltage |
| Output Current | I_OUT | - | 1.2 | - | A | Maximum continuous output current |
| Quiescent Current | I_Q | - | 10 | - | 渭A | Quiescent current at no load |
| Dropout Voltage | V_DROPOUT | - | 250 | - | mV | Dropout voltage at full load |
| Efficiency | 畏 | - | 85 | - | % | Efficiency at typical operating conditions |
| Shutdown Current | I_SHDN | - | 0.1 | - | 渭A | Shutdown mode current |
| Operating Temperature | T_OP | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | T_STG | -65 | - | 150 | 掳C | Storage temperature range |
| Package Type | - | - | SOT-23 | - | - | Package type |
Instructions for Use:
Power Supply Connection:
- Connect the input voltage (V_IN) to the VIN pin.
- Ensure the input voltage is within the specified range (2.7V to 5.5V).
Output Configuration:
- The output voltage (V_OUT) is fixed at 3.3V.
- Connect the output load to the VOUT pin.
Grounding:
- Connect the ground (GND) pin to the common ground of your system.
Capacitors:
- Place a 1渭F ceramic capacitor close to the VIN pin for input filtering.
- Place a 1渭F ceramic capacitor close to the VOUT pin for output filtering.
Shutdown Mode:
- To enable shutdown mode, pull the SHDN pin low (below 0.4V).
- To activate the regulator, pull the SHDN pin high (above 1.2V).
Thermal Considerations:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- The device is designed to operate within the temperature range of -40掳C to 85掳C.
Storage:
- Store the device in a dry environment within the temperature range of -65掳C to 150掳C.
Handling:
- Handle the device with care to avoid damage to the pins and package.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Before final assembly, test the device in a controlled environment to ensure it meets the required specifications.
Regulatory Compliance:
- Ensure that the device complies with all relevant regulatory standards and certifications for your application.
View more about RT425012 on main site