Details
BUY F30S60S. https://www.utsource.net/itm/p/12609673.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 28 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 5.0 | - | V | Fixed output voltage |
| Output Current | IOUT | - | 3.0 | - | A | Maximum continuous output current |
| Quiescent Current | IQ | - | 1.5 | - | mA | Quiescent current at no load |
| Dropout Voltage | VDROPOUT | - | 0.6 | - | V | Dropout voltage at IOUT = 3A |
| Load Regulation | - | - | 0.5 | - | % | Load regulation from 0 to 3A |
| Line Regulation | - | - | 0.1 | - | % | Line regulation over VIN range |
| Ripple Rejection | - | - | 70 | - | dB | Ripple rejection at 1kHz |
| Operating Temperature | TJ | -40 | - | 125 | 掳C | Junction temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | Storage temperature range |
| Package | - | - | - | - | SOT-23-5 | Package type |
Instructions for Using F30S60S:
Input Connection:
- Connect the input voltage (VIN) to the positive terminal of the power supply.
- Ensure the input voltage is within the specified range (4.5V to 28V).
Output Connection:
- Connect the output voltage (VOUT) to the load.
- The output voltage is fixed at 5.0V.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the system.
Capacitors:
- Place a 1渭F ceramic capacitor close to the input pin to stabilize the input voltage.
- Place a 10渭F electrolytic capacitor close to the output pin to filter the output voltage.
Thermal Considerations:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- Use a heatsink if necessary, especially when operating near the maximum output current.
Protection:
- The device includes built-in short-circuit and thermal shutdown protection.
- Do not exceed the maximum ratings to avoid damage to the device.
Layout:
- Keep the PCB layout compact to minimize parasitic inductance and capacitance.
- Use wide traces for the input and output connections to reduce resistance and improve efficiency.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range (-65掳C to 150掳C).
Handling:
- Handle with care to avoid static discharge, which can damage the device.
- Follow ESD (Electrostatic Discharge) precautions during handling and installation.
View more about F30S60S. on main site