| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 2.7 | 3.3 | 5.5 | V |
| Supply Current (Active) | IDD | 10 SPS, 3.3V | - | 1.1 | - | mA |
| Supply Current (Shutdown) | IDD | - | 0.01 | - | 渭A | |
| Differential Input Range | VIN+/- | -0.3 | - | 0.3 | V | |
| Output Data Rate | ODR | 0.49 | 4.9 | 50 | SPS | |
| RTD Bias Current | IBIAS | 140 | 350 | 560 | 渭A | |
| Fault Detection Time | tFD | - | 64 | - | ms | |
| Conversion Time | tCONV | 10 SPS | - | 100 | - | ms |
| Temperature Range | T | Operating | -40 | - | 125 | 掳C |
Instructions for Using the MAX31865ATP
Power Supply:
- Connect the VDD pin to a power supply within the range of 2.7V to 5.5V.
- Connect the GND pin to the ground.
RTD Connection:
- Connect the RTD sensor to the differential input pins (VIN+ and VIN-).
- Ensure the RTD bias current is set appropriately for your application (140渭A to 560渭A).
Configuration:
- Use the configuration register to set the output data rate (ODR), fault detection settings, and other parameters.
- Access the configuration register via the SPI interface.
Data Conversion:
- Initiate a conversion by writing to the appropriate register or using the auto-conversion mode.
- The conversion time is typically 100ms at 10 SPS.
Reading Data:
- After the conversion is complete, read the temperature data from the appropriate registers.
- The data is provided in a digital format, typically in 16-bit resolution.
Fault Detection:
- Monitor the fault status register to check for any faults such as open circuit, short circuit, or over/under temperature conditions.
- The fault detection time is approximately 64ms.
Shutdown Mode:
- To reduce power consumption, put the device into shutdown mode by setting the appropriate bit in the configuration register.
- The supply current in shutdown mode is approximately 0.01渭A.
Temperature Compensation:
- For accurate temperature measurements, use the built-in temperature compensation features or apply external calibration if necessary.
Operating Temperature:
- Ensure the device operates within the temperature range of -40掳C to 125掳C to maintain accuracy and reliability.
SPI Communication:
- Use the SPI interface to communicate with the MAX31865ATP. Ensure the clock frequency is within the supported range and follow the SPI protocol for reading and writing registers.