Details
BUY AN78M18 https://www.utsource.net/itm/p/12609809.html
| Parameter | Description | Value | Unit |
|---|---|---|---|
| Input Voltage | Maximum input voltage the device can handle | 28 | V |
| Output Voltage | Fixed output voltage | 5 | V |
| Output Current | Maximum continuous output current | 1.5 | A |
| Dropout Voltage | Minimum input-output voltage difference for regulation | 1.2 | V |
| Quiescent Current | Current consumed by the regulator itself | 5 | mA |
| Load Regulation | Change in output voltage due to load changes | 0.5 | % |
| Line Regulation | Change in output voltage due to input changes | 0.3 | % |
| Ripple Rejection | Ability to reject ripple from the input | 60 | dB |
| Operating Temperature | Ambient temperature range | -40 to 125 | 掳C |
| Storage Temperature | Temperature range for storage | -65 to 150 | 掳C |
Instructions for AN78M18:
Input Connection:
- Connect the input terminal to a power source that provides an input voltage within the specified range (up to 28V).
Output Connection:
- Ensure the load connected to the output does not exceed the maximum output current of 1.5A.
Grounding:
- Properly connect the ground terminal to ensure stable operation and effective heat dissipation.
Capacitors:
- Place a 0.33渭F capacitor between the input and ground to filter noise.
- Use a 0.1渭F capacitor between the output and ground to stabilize the output voltage.
Heat Sink:
- For applications where the device may approach its thermal limits, consider attaching a heat sink to the package to enhance heat dissipation.
PCB Layout:
- Keep the layout compact to minimize parasitic inductances and capacitances which can affect performance.
- Ensure adequate spacing around the component for cooling purposes.
Operating Conditions:
- Operate the device within the specified temperature ranges to avoid damage or reduced performance.
- Monitor the dropout voltage to ensure the input voltage is sufficiently higher than the output voltage for proper regulation.
View more about AN78M18 on main site