Parameter Symbol Min Typ Max Unit Description
Supply Voltage VCC 4.5 5.0 5.5 V Operating supply voltage range
Output Sensitivity VS 132 135 138 mV/A Magnetic field sensitivity at 25°C
Quiescent Output Voltage VQ 2.4 2.5 2.6 V Output voltage with zero current
Bandwidth BW - 100 - kHz Typical bandwidth
Response Time τ - 2.7 - μs Time to reach 90% of final output
Operating Temperature Toper -40 - 125 °C Operating temperature range
Isolation Voltage VIORM - 2500 - Vrms Reinforced insulation
Current Rating IPR - 50 - A Rated primary conductor current

Instructions for ACS780LLRTR-050U-T

  1. Power Supply Connection:

    • Connect the VCC pin to a 5V power supply within the specified range (4.5V to 5.5V).
    • Ensure that the GND pin is connected to the system ground.
  2. Signal Output:

    • The output voltage (VO) will be proportional to the sensed current.
    • With no current, the output should be around the quiescent output voltage (VQ).
  3. Current Sensing:

    • Place the current-carrying conductor through the center hole of the sensor.
    • Ensure that the current direction matches the arrow on the package for correct polarity.
  4. Temperature Considerations:

    • Operate the device within the specified temperature range (-40°C to +125°C) to ensure reliable performance.
  5. Isolation:

    • The sensor provides reinforced isolation up to 2500 Vrms. Ensure that all connections respect this isolation barrier.
  6. Mounting:

    • Mount the device in a location where it will not be exposed to excessive mechanical stress or vibration.
  7. Handling Precautions:

    • Handle the device with care to avoid damage to the pins and internal components.
    • Follow ESD (Electrostatic Discharge) precautions during handling and installation.
(For reference only)