Details
BUY TLP251F(D4-TP4) https://www.utsource.net/itm/p/12609908.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | - | 4.5 | - | 30 | V |
| Output Current | IOL | VCE = 3.0V, TA = 25掳C | 150 | - | - | mA |
| Forward Voltage | VF | IF = 20mA, TA = 25掳C | - | 1.2 | 1.6 | V |
| Leakage Current | IOL(LEAK) | VCC = 30V, TA = 25掳C | - | - | 10 | 渭A |
| Isolation Voltage | VIORM | - | - | - | 5000 | Vrms |
| Operating Temperature | TOPR | - | -40 | - | 85 | 掳C |
| Storage Temperature | TSTG | - | -55 | - | 125 | 掳C |
| Turn-On Time | tON | IF = 20mA, RL = 100惟, VCC = 5V, TA = 25掳C | - | 1.5 | - | 渭s |
| Turn-Off Time | tOFF | IF = 20mA, RL = 100惟, VCC = 5V, TA = 25掳C | - | 0.5 | - | 渭s |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 4.5V to 30V.
- Avoid exceeding the maximum supply voltage to prevent damage.
Output Current:
- The TLP251F can sink up to 150mA at VCE = 3.0V and TA = 25掳C.
- Ensure the load current does not exceed this limit.
Forward Voltage:
- The forward voltage (VF) is typically 1.2V to 1.6V when the forward current (IF) is 20mA.
- Use this information to design the driving circuit.
Leakage Current:
- The leakage current (IOL(LEAK)) should be less than 10渭A at VCC = 30V and TA = 25掳C.
- This is important for low-power applications.
Isolation Voltage:
- The isolation voltage (VIORM) is 5000Vrms, providing high electrical isolation between the input and output circuits.
- Ensure the isolation requirements of your application are met.
Operating and Storage Temperature:
- The operating temperature (TOPR) range is -40掳C to 85掳C.
- The storage temperature (TSTG) range is -55掳C to 125掳C.
- Store and operate the device within these temperature ranges to ensure reliability.
Turn-On and Turn-Off Times:
- The turn-on time (tON) is typically 1.5渭s, and the turn-off time (tOFF) is typically 0.5渭s under standard conditions.
- These times are crucial for timing-sensitive applications.
Additional Notes:
- Always refer to the datasheet for the most accurate and detailed information.
- Proper heat sinking may be required for continuous operation at higher currents or temperatures.
- Ensure all connections are secure and meet the electrical specifications to avoid damage or malfunction.
View more about TLP251F(D4-TP4) on main site