FRS1B-S5

FRS1B-S5


Specifications
SKU
12610001
Details

BUY FRS1B-S5 https://www.utsource.net/itm/p/12610001.html

Parameter Description Value
Part Number Full part number FRS1B-S5
Type Device type Solid State Relay
Input Voltage (VI) Operating input voltage range 3 to 32 VDC
Input Current (II) Maximum input current 10 mA at 5 VDC
Output Voltage (VO) Output voltage rating 24 to 280 VAC
Output Current (IO) Continuous output current 5 A
Isolation Voltage Isolation between input and output 5000 VAC
Switching Time (tON/tOFF) Turn-on/turn-off time 1 ms / 0.5 ms
Leakage Current (ILK) Maximum leakage current 10 渭A
Operating Temperature (TOP) Operating temperature range -40掳C to +85掳C
Storage Temperature (TSTG) Storage temperature range -55掳C to +125掳C
Mounting Type Method of mounting Surface Mount (SMD)
Package Type Package style SO-8
Dimensions Physical size 9.7 mm x 9.7 mm x 1.4 mm

Instructions for Use:

  1. Power Supply:

    • Ensure the input voltage is within the specified range (3 to 32 VDC).
    • The input current should not exceed 10 mA at 5 VDC.
  2. Load Connection:

    • Connect the load to the output terminals, ensuring the load voltage is within the specified range (24 to 280 VAC).
    • The continuous output current should not exceed 5 A.
  3. Isolation:

    • The relay provides 5000 VAC isolation between the input and output circuits. Ensure proper insulation and spacing to maintain this isolation.
  4. Switching:

    • The relay has a turn-on time of 1 ms and a turn-off time of 0.5 ms. Design your control circuit to accommodate these switching times.
  5. Leakage Current:

    • The maximum leakage current is 10 渭A. This should be considered when designing sensitive circuits.
  6. Temperature Considerations:

    • Operate the relay within the temperature range of -40掳C to +85掳C.
    • Store the relay in an environment with temperatures ranging from -55掳C to +125掳C.
  7. Mounting:

    • Solder the relay onto the PCB using standard SMD soldering techniques.
    • Ensure the board is flat and stable during soldering to avoid mechanical stress on the component.
  8. Handling:

    • Handle the relay with care to avoid damage to the leads and package.
    • Use appropriate ESD protection measures to prevent damage from static electricity.
  9. Testing:

    • Test the relay after installation to ensure it operates correctly under the expected conditions.
    • Verify that the input voltage and current are within the specified limits and that the output can handle the load without exceeding the maximum ratings.
(For reference only)

View more about FRS1B-S5 on main site