Details
BUY SI3240C https://www.utsource.net/itm/p/12610020.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 1.8 | - | 5.5 | V | Operating supply voltage range |
| Quiescent Current | IQ | - | 15 | - | 渭A | Typical quiescent current at VDD = 3.3V |
| Output Current (Source) | IOUT | - | 250 | - | mA | Maximum output current per channel |
| Output Current (Sink) | IOUT | - | 250 | - | mA | Maximum output current per channel |
| Output Voltage Drop | VDROPS | - | 0.4 | - | V | Voltage drop when sourcing 250mA |
| Output Voltage Drop | VDROPS | - | 0.4 | - | V | Voltage drop when sinking 250mA |
| Thermal Shutdown | TSD | - | 160 | - | 掳C | Thermal shutdown temperature |
| Operating Temperature | TOPR | -40 | - | 125 | 掳C | Operating ambient temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for Using the SI3240C
Supply Voltage:
- Ensure the supply voltage (VDD) is within the range of 1.8V to 5.5V.
- Use a stable power source to avoid fluctuations that could affect performance.
Quiescent Current:
- The typical quiescent current is 15渭A at VDD = 3.3V. This value can help in power budget calculations.
Output Current:
- The maximum output current per channel is 250mA for both sourcing and sinking.
- Do not exceed this limit to prevent damage to the device.
Output Voltage Drop:
- When sourcing or sinking 250mA, the voltage drop across the output is typically 0.4V.
- Consider this drop when designing your circuit to ensure proper operation of connected components.
Thermal Shutdown:
- The device will automatically shut down if the junction temperature reaches 160掳C to prevent thermal damage.
- Ensure adequate heat dissipation, especially in high-power applications.
Operating Temperature:
- The operating ambient temperature range is from -40掳C to 125掳C.
- Avoid operating the device outside this range to maintain reliability.
Storage Temperature:
- Store the device in an environment with temperatures ranging from -65掳C to 150掳C to prevent damage during storage.
Handling and Installation:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Follow proper soldering techniques and use recommended reflow profiles to ensure reliable connections.
Testing and Verification:
- After installation, verify the functionality of the device by testing the output currents and voltages under various load conditions.
- Monitor the temperature to ensure it remains within safe limits during operation.
View more about SI3240C on main site