MAX31865AAP+T

MAX31865AAP+T


Specifications
Details

BUY MAX31865AAP+T https://www.utsource.net/itm/p/12610028.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating 3.0 5.5 V
Supply Current IDD No RTD connected 1.6 mA
RTD Excitation Current IEXC 0.375 0.375 mA
Temperature Range RTD -200 +850 掳C
Fault Detection Open, short, overtemp Yes
SPI Interface Mode 0, 3 Yes
Output Data Rate Configurable 10 50 Hz

Instructions for MAX31865AAP+T:

  1. Power Supply:

    • Connect the VDD pin to a power supply within the range of 3.0V to 5.5V.
    • Ensure the supply current does not exceed 1.6mA.
  2. RTD Connection:

    • Connect the RTD (Resistance Temperature Detector) to the appropriate pins on the MAX31865AAP+T.
    • The device provides a constant excitation current of 0.375mA to the RTD.
  3. Temperature Measurement:

    • The device can measure temperatures from -200掳C to +850掳C using the connected RTD.
    • Configure the output data rate as needed between 10Hz and 50Hz.
  4. Fault Detection:

    • The device includes built-in fault detection for open, short circuits, and overtemperature conditions.
    • Monitor the fault status through the SPI interface.
  5. SPI Communication:

    • Use the SPI interface in Mode 0 or 3 to communicate with the device.
    • Ensure proper configuration of the SPI settings according to your microcontroller setup.
  6. Configuration:

    • Set up the device using the configuration registers accessible via the SPI interface.
    • Refer to the datasheet for detailed register maps and configuration options.
(For reference only)

View more about MAX31865AAP+T on main site