Details
BUY JQC-25F018-H(555) https://www.utsource.net/itm/p/12610112.html
| Parameter | Description | Value |
|---|---|---|
| Type | Relay Type | SPDT (Single Pole Double Throw) |
| Model | Model Number | JQC-25F018-H(555) |
| Coil Voltage | Nominal Coil Voltage | 5V DC |
| Coil Current | Nominal Coil Current | 36mA |
| Coil Resistance | Nominal Coil Resistance | 139Ω |
| Contact Form | Contact Configuration | 1C/O (1 Changeover) |
| Contact Rating | Maximum Switching Capacity | 10A at 250V AC, 10A at 30V DC |
| Insulation Resistance | Minimum Insulation Resistance | 100MΩ at 500V DC |
| Dielectric Strength | Dielectric Strength | 2500V AC for 1 minute |
| Operating Temperature | Operating Temperature Range | -40°C to +85°C |
| Storage Temperature | Storage Temperature Range | -40°C to +125°C |
| Mechanical Life | Mechanical Life | 10 million operations |
| Electrical Life | Electrical Life | 100,000 operations (resistive load) |
| Operate Time | Operate Time | ≤10ms |
| Release Time | Release Time | ≤5ms |
| Weight | Weight | 10g |
Instructions:
Installation:
- Ensure that the relay is installed in a location where it will not be exposed to excessive heat, moisture, or mechanical shock.
- Mount the relay on a flat, stable surface using the provided mounting holes.
Wiring:
- Connect the coil terminals to the control circuit according to the polarity indicated on the relay.
- Connect the common (COM), normally open (NO), and normally closed (NC) contacts to the load circuit as required.
Operation:
- When the coil is energized, the relay will switch the contacts from the NC position to the NO position.
- When the coil is de-energized, the contacts will return to their default NC position.
Testing:
- Use a multimeter to verify the continuity of the contacts before and after energizing the coil.
- Ensure that the relay operates within the specified operating temperature range.
Maintenance:
- Regularly inspect the relay for signs of wear or damage.
- Replace the relay if it fails to operate correctly or if the contacts show signs of excessive wear.
Safety:
- Do not exceed the maximum switching capacity of the relay.
- Ensure that the relay is disconnected from the power source before performing any maintenance or testing.