Details
BUY SERCON816 https://www.utsource.net/itm/p/12610129.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Device Identifier | SERCON816 |
| Type | Device Type | Serial EEPROM |
| Capacity | Memory Size | 8 Kbit (1024 x 8) |
| Voltage Supply | Operating Voltage Range | 2.5V to 5.5V |
| Current | Active Current (Typical) | 1.0 mA |
| Standby Current | Standby Current (Typical) | 1.0 渭A |
| Interface | Communication Protocol | I2C |
| Operating Temperature | Temperature Range for Operation | -40掳C to +85掳C |
| Package | Physical Package Type | SOIC-8, TSSOP-8 |
| Write Cycle Time | Time Required for a Write Operation | 5 ms |
| Endurance | Number of Write/Erase Cycles | 1,000,000 cycles |
| Data Retention | Minimum Data Retention Time | 100 years |
| Ordering Information | Part Number for Ordering | SERCON816-SOIC8, SERCON816-TSSOP8 |
Instructions for Use
Power Supply:
- Ensure the supply voltage is within the specified range of 2.5V to 5.5V.
- Connect VCC to the positive power supply and GND to the ground.
I2C Interface:
- The device uses the I2C protocol for communication.
- Connect SDA (Serial Data) and SCL (Serial Clock) lines to the corresponding pins on the microcontroller or other I2C master device.
- Pull-up resistors are required on both SDA and SCL lines. Typical values range from 1.8k惟 to 10k惟, depending on the bus length and speed.
Address Configuration:
- The device has a fixed I2C address. Refer to the datasheet for the specific address.
- If multiple devices are used on the same bus, ensure they have unique addresses.
Write Operation:
- Start the I2C communication with a start condition.
- Send the device address followed by the write command.
- Send the memory address where data is to be written.
- Send the data to be written.
- End the communication with a stop condition.
- Wait for the write cycle to complete (5 ms).
Read Operation:
- Start the I2C communication with a start condition.
- Send the device address followed by the write command.
- Send the memory address from which data is to be read.
- Restart the communication with another start condition.
- Send the device address followed by the read command.
- Read the data from the device.
- End the communication with a stop condition.
Power Management:
- To reduce power consumption, place the device in standby mode when not in use.
- In standby mode, the device consumes approximately 1.0 渭A.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.
- Store the device in a dry, cool environment to prevent moisture damage.
View more about SERCON816 on main site