IKW75N60T

IKW75N60T


Specifications
SKU
12610216
Details

BUY IKW75N60T https://www.utsource.net/itm/p/12610216.html

Parameter Symbol Min Typ Max Unit Conditions
Collector-Emitter Voltage VCEO - - 600 V IC = 25 A, Tj = 25掳C
Emitter-Collector Voltage VECS - - 600 V IC = 25 A, Tj = 25掳C
Gate-Emitter Voltage (Max) VGE(max) - - 卤20 V -
Continuous Collector Current IC - 75 - A TC = 25掳C
Continuous Collector Current IC - 53 - A TC = 100掳C
Pulse Collector Current ICM - 200 - A tp = 10 ms, IGT = 2 A, Tj = 25掳C
Total Power Dissipation PTOT - - 240 W TC = 25掳C
Junction to Case Thermal Resistance Rth(j-c) - 0.4 - K/W -
Junction to Ambient Thermal Resistance Rth(j-a) - 60 - K/W -
Storage Temperature Range Tstg -55 - 150 掳C -
Operating Junction Temperature Range Top(j) -55 - 150 掳C -

Instructions for Use:

  1. Handling and Storage:

    • Store the device in a dry, cool place to avoid moisture damage.
    • Handle the device with care to prevent mechanical damage.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the specified limits.
    • Use a thermal interface material (TIM) between the device and the heat sink for efficient heat dissipation.
  3. Electrical Connections:

    • Connect the gate and emitter terminals with short leads to minimize parasitic inductance.
    • Ensure that the gate drive circuit can provide the necessary current to charge and discharge the gate capacitance quickly.
  4. Overvoltage Protection:

    • Implement overvoltage protection circuits to safeguard against voltage spikes that could exceed the maximum ratings.
  5. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed the maximum operating temperature.
    • Use forced air cooling or liquid cooling if necessary to manage heat effectively.
  6. Gate Drive:

    • Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
    • Ensure the gate drive voltage is within the specified range to avoid damaging the gate oxide.
  7. Safe Operating Area (SOA):

    • Refer to the SOA graph provided in the datasheet to ensure the device operates within safe limits under all conditions.
  8. Derating:

    • Derate the continuous collector current as the case temperature increases to ensure reliable operation.
  9. Testing:

    • Perform initial testing at low power levels to verify correct operation before moving to higher power applications.
  10. Compliance:

    • Ensure compliance with relevant safety and regulatory standards for your application.
(For reference only)

View more about IKW75N60T on main site