Details
BUY CPC1017N https://www.utsource.net/itm/p/12610263.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 2.7 | - | 5.5 | V | - |
| Supply Current | IDD | - | 0.1 | 0.5 | mA | VDD = 3.3V, No Load |
| Input Voltage Range | VIN | 0 | - | 5.5 | V | - |
| Output Voltage Range | VOUT | 0 | - | 5.5 | V | - |
| Maximum Output Current | IOUT | - | 100 | 150 | mA | VDD = 5.5V |
| Operating Temperature | TOP | -40 | - | 85 | 掳C | - |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | - |
| Quiescent Current | IQ | - | 0.1 | 0.5 | mA | VDD = 3.3V, No Load |
| Output Ripple | VRIPPLE | - | 30 | 50 | mV | VDD = 5.5V, 100mA |
| Load Regulation | - | - | 0.5 | 1.0 | % | VDD = 5.5V, 0-100mA |
| Line Regulation | - | - | 0.1 | 0.5 | % | VDD = 2.7-5.5V, No Load |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- Connect the supply voltage to the VDD pin and ground to the GND pin.
Input and Output Connections:
- Connect the input signal to the VIN pin.
- Connect the output load to the VOUT pin.
- Ensure the output current does not exceed 150mA to avoid damage.
Temperature Considerations:
- The device is designed to operate within the temperature range of -40掳C to 85掳C.
- Store the device in an environment with temperatures between -65掳C and 150掳C.
Load and Line Regulation:
- The load regulation is typically 0.5% and should not exceed 1.0%.
- The line regulation is typically 0.1% and should not exceed 0.5%.
Quiescent Current:
- The quiescent current is very low, typically 0.1mA, and should not exceed 0.5mA under no-load conditions.
Output Ripple:
- The output ripple is typically 30mV and should not exceed 50mV under a 100mA load.
Supply Current:
- The supply current is typically 0.1mA and should not exceed 0.5mA under no-load conditions.
Handling and Storage:
- Handle the device with care to avoid static discharge.
- Store the device in a dry and cool place to prevent moisture damage.
Testing:
- Before using the device in a final application, test it under typical operating conditions to ensure it meets the required specifications.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your application.