Parameter Symbol Min Typical Max Units Conditions
Supply Voltage Vcc 4.5 30 V
Supply Current Icc 1.2 mA Vcc = 5V, 25°C
Output Current Iout 20 mA
Temperature Range -40 125 °C
Accuracy ±1 % 25°C, Vcc = 5V
Linearity ±0.1 % 25°C, Vcc = 5V
Hysteresis 0.02 % 25°C, Vcc = 5V
Thermal Coefficient α 0.085 %/°C 25°C to 125°C, Vcc = 5V
Zero Offset Vos 5 mV 25°C, Vcc = 5V
Span Span 10 mV/°C 25°C, Vcc = 5V
Response Time τ 5 s 25°C, Vcc = 5V
Operating Humidity 0 95 % RH Non-condensing
Storage Temperature -65 150 °C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the specified range of 4.5V to 30V.
    • The typical supply current (Icc) is 1.2mA at 5V.
  2. Temperature Measurement:

    • The AD594AQ provides a linear output current proportional to the temperature.
    • The output current can be converted to a voltage using a precision resistor.
    • The span of the output is typically 10mV/°C.
  3. Calibration:

    • Calibrate the device at 25°C to ensure accuracy.
    • Adjust the zero offset (Vos) and span as needed to match the desired temperature range.
  4. Environmental Considerations:

    • Operate the device within the specified temperature range of -40°C to 125°C.
    • Store the device within the storage temperature range of -65°C to 150°C.
    • Ensure the operating humidity does not exceed 95% RH (non-condensing).
  5. Response Time:

    • The response time (τ) is approximately 5 seconds at 25°C and 5V supply.
  6. Thermal Coefficient:

    • The thermal coefficient (α) is 0.085%/°C from 25°C to 125°C, which affects the accuracy over the temperature range.
  7. Hysteresis:

    • The hysteresis is 0.02%, which should be considered in applications where temperature cycling is frequent.
  8. Linearity:

    • The linearity is ±0.1%, ensuring a consistent and reliable output over the temperature range.
  9. Mounting:

    • Mount the device in a location where it is not subject to mechanical stress or vibration that could affect its performance.
  10. Handling:

    • Handle the device with care to avoid damage to the pins and internal components.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device.

By following these instructions, you can ensure optimal performance and reliability of the AD594AQ temperature sensor.