Details
BUY TLP759(TP1,J,F) https://www.utsource.net/itm/p/12610318.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Forward Current | IF | - | 10 | 20 | mA | |
| Peak Forward Current | IFM | - | - | 30 | mA | t = 10 ms, repetition rate 100/s |
| Reverse Voltage | VR | - | - | 5 | V | |
| Forward Voltage | VF | 1.1 | 1.3 | 1.6 | V | IF = 10 mA |
| Output Current | IOL | 4.5 | 8 | 11 | mA | VDD = 5 V, RL = 300 惟 |
| Output Leakage Current | IOL(LEAK) | - | - | 0.1 | 渭A | VDD = 5 V, IL = 0 mA |
| Propagation Delay Time | tpLH | 25 | 35 | 45 | ns | IF = 10 mA, VDD = 5 V, RL = 300 惟 |
| Propagation Delay Time | tpHL | 25 | 35 | 45 | ns | IF = 10 mA, VDD = 5 V, RL = 300 惟 |
| Storage Temperature | Tstg | -40 | - | 85 | 掳C | |
| Operating Temperature | Topr | 0 | - | 70 | 掳C |
Instructions for Use:
- Forward Current (IF): Ensure that the forward current does not exceed 20 mA continuously to avoid damaging the device.
- Peak Forward Current (IFM): The peak forward current should not exceed 30 mA for more than 10 ms, with a repetition rate of 100 times per second.
- Reverse Voltage (VR): Do not apply a reverse voltage greater than 5 V to prevent breakdown.
- Forward Voltage (VF): The forward voltage at 10 mA is typically between 1.1 V and 1.6 V.
- Output Current (IOL): The output current can range from 4.5 mA to 11 mA when VDD is 5 V and the load resistance (RL) is 300 惟.
- Output Leakage Current (IOL(LEAK)): The leakage current should not exceed 0.1 渭A under normal operating conditions.
- Propagation Delay Time (tpLH, tpHL): The propagation delay time for both low-to-high and high-to-low transitions is typically 35 ns, with a range of 25 ns to 45 ns.
- Storage Temperature (Tstg): Store the device in an environment where the temperature ranges from -40掳C to 85掳C.
- Operating Temperature (Topr): Operate the device within a temperature range of 0掳C to 70掳C to ensure reliable performance.
Additional Notes:
- Always ensure that the power supply voltage (VDD) and load resistance (RL) are within the specified limits.
- Proper heat sinking may be required for continuous operation at higher currents or temperatures.
- For detailed application circuits and further information, refer to the datasheet provided by the manufacturer.