| Parameter | Description | Value | Unit |
|---|---|---|---|
| Part Number | Device Identifier | MK50283N | - |
| Type | Device Type | Low Dropout Linear Regulator (LDO) | - |
| Input Voltage Range | Operating Input Voltage | 1.7 to 5.5 | V |
| Output Voltage | Fixed Output Voltage | 3.3 | V |
| Output Current | Maximum Continuous Output Current | 200 | mA |
| Dropout Voltage | Maximum Dropout Voltage at 200mA | 250 | mV |
| Quiescent Current | Typical Quiescent Current | 60 | 渭A |
| Shutdown Current | Typical Shutdown Current | 0.1 | 渭A |
| PSRR | Power Supply Rejection Ratio at 1kHz | 60 | dB |
| Line Regulation | Line Regulation | 0.01 | %/V |
| Load Regulation | Load Regulation | 0.01 | %/mA |
| Operating Temperature Range | Ambient Operating Temperature | -40 to 85 | 掳C |
| Storage Temperature Range | Storage Temperature | -65 to 150 | 掳C |
| Package | Package Type | SOT-23-5 | - |
Instructions for Use:
Circuit Design:
- Connect the input voltage to the VIN pin.
- Connect the output voltage to the VOUT pin.
- Ground the GND pin.
- Connect a capacitor (typically 1 渭F) between VOUT and GND for stability.
- Optionally, connect a capacitor (typically 10 nF) between VIN and GND to filter input noise.
Power-Up Sequence:
- Ensure the input voltage is within the specified range before applying power.
- Gradually increase the input voltage to avoid inrush current issues.
Thermal Management:
- Ensure adequate heat dissipation, especially when operating at high output currents.
- Consider using a heatsink or thermal pad if the device is expected to operate near its maximum output current.
Shutdown Operation:
- To shut down the device, pull the SHDN pin low.
- When the SHDN pin is high or left floating, the device is active.
Storage and Handling:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the device.
Testing:
- Verify the output voltage and current capabilities using a multimeter and load resistor.
- Test the line and load regulation by varying the input voltage and load current while monitoring the output voltage.
Safety:
- Do not exceed the maximum ratings specified in the datasheet.
- Ensure proper grounding and isolation to avoid electrical hazards.
View more about MK50283N on main site