Details
BUY L6206D https://www.utsource.net/itm/p/12610448.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating | 8 | - | 30 | V |
| Quiescent Current | IQ | No load | - | 10 | - | mA |
| Output Current (Max) | Iout | Continuous | - | - | 500 | mA |
| Thermal Shutdown | TSD | Activation | - | 160 | - | 掳C |
| Operating Temperature | Topr | Junction | -40 | - | 125 | 掳C |
| Storage Temperature | Tstg | -40 | - | 150 | 掳C |
Instructions for L6206D:
Power Supply Connection:
- Connect the supply voltage between the Vcc and GND pins. Ensure the supply voltage is within the specified range of 8V to 30V.
Heat Dissipation:
- The device has an internal thermal shutdown mechanism that activates at approximately 160掳C. To prevent overheating, ensure adequate heat dissipation, especially when operating at higher currents or temperatures.
Output Current Limitation:
- Do not exceed the maximum continuous output current of 500mA. For applications requiring higher currents, consider using external components or a different device.
Temperature Considerations:
- Operate the device within the junction temperature range of -40掳C to 125掳C. Store the device in environments where the temperature does not exceed 150掳C.
Quiescent Current:
- Be aware that the quiescent current is typically 10mA with no load. This should be factored into power budget calculations.
Handling Precautions:
- Follow standard precautions for handling electronic components, including anti-static measures, to avoid damage to the device.
View more about L6206D on main site