24NM65N.

24NM65N.


Specifications
SKU
12610471
Details

BUY 24NM65N. https://www.utsource.net/itm/p/12610471.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS - - 650 V
Gate-Source Voltage VGS -10 - 20 V
Continuous Drain Current ID - 24 - A @ Tc = 25掳C
Pulse Drain Current Ipp - 96 - A tp = 10 渭s, Tc = 25掳C
Power Dissipation PD - - 270 W @ Tc = 25掳C
Junction Temperature TJ -55 - 175 掳C
Storage Temperature TSTG -55 - 150 掳C
Thermal Resistance R胃JC - 0.75 - 掳C/W Case to Junction
Total Gate Charge Qg - 135 - nC @ VGS = 15V, IDS = 24A
Input Capacitance Ciss - 2800 - pF @ VDS = 650V, VGS = 0V
Output Capacitance Coss - 1300 - pF @ VDS = 650V, VGS = 0V
Reverse Transfer Capacitance Crss - 600 - pF @ VDS = 650V, VGS = 0V

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to maintain the junction temperature within the specified limits.
    • Handle the device with care to avoid mechanical stress and static discharge.
  2. Electrical Connections:

    • Connect the drain (D) to the high-voltage side of the circuit.
    • Connect the source (S) to the low-voltage side or ground.
    • Apply the gate (G) voltage relative to the source (S) to control the device.
  3. Gate Drive:

    • Use a gate driver capable of providing the necessary current to charge and discharge the gate capacitance quickly.
    • Ensure the gate voltage is within the specified range to prevent damage to the device.
  4. Thermal Management:

    • Monitor the junction temperature and use appropriate cooling methods (e.g., heatsinks, fans) to keep it within safe limits.
    • Consider derating the power dissipation if operating at higher ambient temperatures.
  5. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage from excessive current.
    • Use fast-acting fuses or current-limiting circuits.
  6. Storage and Transportation:

    • Store the device in a dry, cool environment away from direct sunlight.
    • Follow ESD (Electrostatic Discharge) precautions during handling and transportation.
  7. Testing:

    • Test the device under controlled conditions to ensure it meets the specified parameters.
    • Use appropriate test equipment and follow safety guidelines to avoid damage to the device or injury.
  8. Compliance:

    • Ensure that the device is used in compliance with all relevant safety and regulatory standards.
(For reference only)

View more about 24NM65N. on main site