Details
BUY CHS01-S-124LB https://www.utsource.net/itm/p/12610527.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Component Identifier | CHS01-S-124LB |
| Type | Component Type | Hall Effect Sensor |
| Operating Voltage (VCC) | Supply Voltage Range | 3.3V to 5.5V |
| Output Type | Output Signal Type | Digital (Open Collector) |
| Quiescent Current (Iq) | Current Consumption at No Load | ≤ 1.5mA |
| Magnetic Sensitivity (Bop) | Magnetic Field for Operation | 30 Gauss (Typical) |
| Release Sensitivity (Brp) | Magnetic Field for Release | 15 Gauss (Typical) |
| Operating Temperature (Toper) | Operating Temperature Range | -40°C to 85°C |
| Storage Temperature (Tstg) | Storage Temperature Range | -40°C to 150°C |
| Response Time | Time to Switch State | ≤ 100μs |
| Output Low Voltage (VOL) | Output Voltage when Low | ≤ 0.4V (at 10mA) |
| Output High Impedance | Output State when High | > 10kΩ |
| Package Type | Physical Package | SOT-23-3 |
| Polarity | Magnetic Field Polarity Sensitivity | Bipolar |
| Mounting | Mounting Style | Surface Mount |
Instructions for Use:
Power Supply:
- Connect the VCC pin to a power supply within the range of 3.3V to 5.5V.
- Connect the GND pin to the ground of the power supply.
Output Connection:
- The output is an open collector, so connect a pull-up resistor between the output pin (OUT) and VCC.
- The typical value for the pull-up resistor is 4.7kΩ to 10kΩ.
Magnetic Field Application:
- Place a magnet near the sensor to activate it. The sensor will switch its output state based on the magnetic field strength.
- For operation, the magnetic field should exceed the Bop threshold (30 Gauss typical).
- For release, the magnetic field should drop below the Brp threshold (15 Gauss typical).
Temperature Considerations:
- Ensure that the operating temperature remains within the specified range (-40°C to 85°C).
- Store the sensor in an environment where the temperature does not exceed 150°C.
Handling and Storage:
- Handle the sensor with care to avoid damage.
- Store in a dry and cool place to prevent moisture damage.
Testing:
- Before integrating the sensor into a circuit, test it using a known magnetic field to ensure proper functionality.
- Use a multimeter to verify the output state (LOW or HIGH) when the magnetic field is applied and removed.