Details
BUY IRG4BC30FD https://www.utsource.net/itm/p/12610629.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Maximum Drain-to-Source Voltage | VDS | - | 600 | - | V | |
| Maximum Gate-to-Source Voltage | VGS | -15 | 20 | V | ||
| Maximum Continuous Drain Current | ID | - | 30 | - | A | TC = 25掳C |
| Maximum Pulse Drain Current | IDM | - | 90 | - | A | tp = 10 渭s, TC = 25掳C |
| Power Dissipation | PTOT | - | 180 | - | W | TC = 25掳C |
| Junction Temperature | TJ | - | 175 | 掳C | ||
| Storage Temperature Range | TSTG | -55 | 150 | 掳C | ||
| Total Gate Charge | QG | - | 105 | - | nC | VGS = 15V, ID = 10A |
| Input Capacitance | Ciss | - | 2300 | - | pF | VDS = 400V, f = 1 MHz |
| Output Capacitance | Coss | - | 115 | - | pF | VDS = 400V, f = 1 MHz |
| Reverse Transfer Capacitance | Crss | - | 240 | - | pF | VDS = 400V, f = 1 MHz |
| Turn-On Delay Time | td(on) | - | 26 | - | ns | VGS = 15V, ID = 10A |
| Rise Time | tr | - | 40 | - | ns | VGS = 15V, ID = 10A |
| Turn-Off Delay Time | td(off) | - | 22 | - | ns | VGS = -15V, ID = 10A |
| Fall Time | tf | - | 36 | - | ns | VGS = -15V, ID = 10A |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to manage the power dissipation.
- Handle the device with care to avoid static damage.
Biasing:
- Apply the gate-to-source voltage (VGS) within the specified range to avoid damage.
- Ensure the drain-to-source voltage (VDS) does not exceed the maximum rating.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it remains within safe limits.
- Use appropriate cooling methods such as heatsinks or forced air cooling.
Pulse Operation:
- For pulse operation, ensure that the pulse duration (tp) and current (IDM) are within the specified limits to prevent overheating.
Capacitance Considerations:
- Account for the input (Ciss), output (Coss), and reverse transfer (Crss) capacitances when designing the circuit to ensure stability and performance.
Switching Characteristics:
- Use the turn-on delay time (td(on)), rise time (tr), turn-off delay time (td(off)), and fall time (tf) to optimize the switching performance and minimize losses.
Storage and Transportation:
- Store the device in a dry, cool environment and protect it from static electricity.
- Follow recommended handling procedures during transportation to avoid physical damage.
View more about IRG4BC30FD on main site