| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 4.75 | 5.0 | 5.25 | V | - |
| Output Current per Channel | IO | 0 | 120 | 150 | mA | Continuous, Ta = 25°C |
| Peak Output Current per Channel | IOPK | - | 160 | 200 | mA | Pulse Width ≤ 1 ms, Duty Cycle ≤ 5% |
| Input Voltage Range | VIN | 0 | - | VDD | V | - |
| High-Level Input Voltage | VIH | 3.5 | - | VDD | V | - |
| Low-Level Input Voltage | VIL | 0 | - | 1.5 | V | - |
| High-Level Output Voltage | VOH | 4.4 | - | VDD - 0.1 | V | IO = 150 mA, Ta = 25°C |
| Low-Level Output Voltage | VOL | 0 | - | 0.5 | V | IO = 150 mA, Ta = 25°C |
| Power Dissipation | PD | - | - | 1500 | mW | Ta = 25°C |
| Operating Temperature Range | TOPR | -40 | 25 | 85 | °C | - |
| Storage Temperature Range | TSTG | -65 | - | 150 | °C | - |
Instructions for Using MBI5026GD
Supply Voltage (VDD):
- Ensure the supply voltage is within the range of 4.75V to 5.25V.
- Use a stable power source to avoid fluctuations that could affect performance.
Output Current (IO):
- The continuous output current per channel should not exceed 150mA.
- For peak currents up to 200mA, ensure the pulse width is ≤ 1ms and the duty cycle is ≤ 5%.
Input Voltage Range (VIN):
- The input voltage should be between 0V and VDD.
- Ensure high-level input voltages (VIH) are at least 3.5V and low-level input voltages (VIL) are no more than 1.5V for reliable operation.
Output Voltage Levels:
- When sourcing 150mA, the high-level output voltage (VOH) should be at least 4.4V.
- When sinking 150mA, the low-level output voltage (VOL) should be no more than 0.5V.
Power Dissipation (PD):
- The maximum power dissipation is 1500mW at 25°C ambient temperature.
- Ensure adequate heat dissipation if operating near this limit.
Operating Temperature (TOPR):
- The device is designed to operate between -40°C and 85°C.
- Avoid operating outside this range to prevent damage or reduced performance.
Storage Temperature (TSTG):
- Store the device between -65°C and 150°C to ensure long-term reliability.
Handling Precautions:
- Handle with care to avoid static discharge, which can damage the device.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Mounting:
- Ensure proper mounting to a suitable PCB with appropriate thermal management.
- Use recommended soldering profiles to avoid thermal stress.
Testing:
- Perform initial testing under controlled conditions to verify correct operation.
- Monitor performance parameters regularly to ensure ongoing reliability.
View more about MBI5026GD on main site