INA219AID SOIC-8

INA219AID SOIC-8


Specifications
Details

BUY INA219AID SOIC-8 https://www.utsource.net/itm/p/12610708.html

Parameter Symbol Test Conditions Min Typical Max Unit
Supply Voltage VDD 3.0 5.5 V
Operating Temperature TOPR -40 85 掳C
Shutdown Current ISD VIN = 5V 0.1 渭A
Quiescent Current IQ VIN = 5V, IOUT = 0mA 0.4 mA
Differential Input Voltage VDIFF 卤320 mV
Common-Mode Input Voltage VCM 0 26.4 V
Bus Voltage Range VB 0 26.4 V
Maximum Power Dissipation PDISS TA = 25掳C 700 mW

Instructions for INA219AID SOIC-8

  1. Power Supply Connection:

    • Connect the power supply to the VDD and GND pins. Ensure the supply voltage is within the specified range of 3.0V to 5.5V.
  2. Bus Voltage Measurement:

    • Connect the bus voltage (VB) to the VBUS pin. The common-mode input voltage can range from 0V to 26.4V.
  3. Shunt Voltage Measurement:

    • Connect the shunt resistor across the VSHUNT+ and VSHUNT- pins. The differential input voltage should not exceed 卤320mV.
  4. Configuration:

    • Use the I2C interface to configure the device settings such as averaging, bus voltage range, and conversion time.
  5. Shutdown Mode:

    • To enter shutdown mode, set the appropriate bit in the configuration register. This reduces the current consumption to approximately 0.1渭A.
  6. Temperature Considerations:

    • Ensure that the operating temperature remains between -40掳C and 85掳C to maintain performance specifications.
  7. Power Dissipation:

    • Keep the maximum power dissipation below 700mW to avoid overheating. Ensure adequate heat sinking if operating near this limit.
  8. Handling Static Electricity:

    • The device is sensitive to static electricity. Follow proper handling procedures to prevent damage.

Note: Always refer to the latest datasheet from the manufacturer for detailed information and updates.

(For reference only)

View more about INA219AID SOIC-8 on main site