EM4095

EM4095


Specifications
SKU
12610739
Details

BUY EM4095 https://www.utsource.net/itm/p/12610739.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating voltage range
Operating Current IDD - 10 - 渭A Typical current consumption at 3.3V, 125 kHz
Data Rate - 16 - kbps Maximum data rate
Operating Frequency fosc 100 - 150 kHz Oscillator frequency range
Modulation Index MI 10 - 20 % Recommended modulation index for optimal performance
Output Voltage Swing Vswing 0.5 - 3.3 V Output voltage swing range
Input Capacitance Cin - 10 - pF Typical input capacitance
Output Capacitance Cout - 10 - pF Typical output capacitance
Temperature Range Toper -40 - 85 掳C Operating temperature range
Storage Temperature Tstg -40 - 125 掳C Storage temperature range

Instructions for Using the EM4095

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
    • Connect the VDD pin to the power source and GND to the ground.
  2. Oscillator Configuration:

    • The EM4095 operates with an external oscillator in the range of 100 kHz to 150 kHz.
    • Connect the external oscillator to the XTAL1 and XTAL2 pins.
  3. Data Communication:

    • The EM4095 supports a maximum data rate of 16 kbps.
    • Connect the data lines (TXD and RXD) to the microcontroller or other communication interfaces.
  4. Modulation:

    • Use a modulation index (MI) between 10% and 20% for optimal performance.
    • The modulation can be achieved using the MOD pin.
  5. Output Configuration:

    • The output voltage swing should be set between 0.5V and 3.3V.
    • Use appropriate resistors or voltage dividers to set the output level.
  6. Capacitance Considerations:

    • The typical input capacitance (Cin) and output capacitance (Cout) are both around 10 pF.
    • Ensure that the external components do not significantly affect these values.
  7. Temperature Range:

    • The EM4095 operates reliably within the temperature range of -40掳C to 85掳C.
    • For storage, ensure the device is kept within the range of -40掳C to 125掳C.
  8. Testing and Troubleshooting:

    • Verify the supply voltage and connections before testing.
    • Use an oscilloscope to check the signal integrity on the data lines and oscillator pins.
    • Refer to the datasheet for detailed troubleshooting steps and additional information.
(For reference only)

View more about EM4095 on main site