| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Collector-Emitter Breakdown Voltage | V(BR)CEO | IC = 0, IE = 0 | 120 | - | - | V |
| Emitter-Base Breakdown Voltage | V(BR)EBO | IC = 0, IE = 0 | 7 | - | - | V |
| Collector Current | IC | VCE = 30V, T = 25掳C | - | 5 | - | A |
| Power Dissipation | PD | Tc = 25掳C | - | - | 65 | W |
| Junction Temperature | TJ | - | - | - | 150 | 掳C |
| Storage Temperature Range | TSTG | - | -55 | - | 150 | 掳C |
Instructions for MJF6388:
- Handling Precautions: The MJF6388 is sensitive to electrostatic discharge (ESD). Use proper anti-static precautions when handling the device.
- Mounting: Ensure that the device is mounted in a way that allows adequate heat dissipation, especially if operating near the maximum power dissipation limit.
- Biasing: Carefully set the biasing conditions to avoid exceeding the maximum ratings for collector-emitter and emitter-base voltages.
- Operating Temperatures: Monitor the junction temperature to ensure it does not exceed 150掳C. This can be managed through heatsinking or by reducing the load.
- Storage: Store the device in a controlled environment within the specified storage temperature range (-55掳C to 150掳C).
- Testing: When testing the device, ensure all parameters are within the specified limits to avoid damage.
View more about MJF6388 on main site