Details
BUY HCPL-0611-000E https://www.utsource.net/itm/p/12610858.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | IF = 20 mA | - | 1.2 | 1.5 | V |
| Reverse Voltage | VR | IR = 1 渭A | - | - | 5.5 | V |
| Forward Current | IF | Continuous | - | - | 50 | mA |
| Peak Forward Current | IF(peak) | 10% Duty Cycle | - | - | 150 | mA |
| Output Current (High Level) | IOH | VO = 4.5 V, TA = 25掳C | - | - | 30 | mA |
| Output Current (Low Level) | IOL | VO = 0.4 V, TA = 25掳C | 8 | 15 | - | mA |
| Isolation Voltage | VIORM | 1 Minute, 50/60 Hz | - | - | 3750 | Vrms |
| Operating Temperature Range | TA | - | -40 | - | 105 | 掳C |
| Storage Temperature Range | TSTG | - | -55 | - | 125 | 掳C |
Instructions for Use:
Power Supply:
- Ensure the power supply voltage is within the specified range to avoid damage.
- Use a stable power source to maintain consistent operation.
Forward Current:
- Do not exceed the maximum forward current (IF) of 50 mA continuously.
- For peak applications, ensure the duty cycle does not exceed 10% and the peak current does not exceed 150 mA.
Output Current:
- When the output is high, the maximum current (IOH) should not exceed 30 mA.
- When the output is low, the minimum current (IOL) should be at least 8 mA, with a typical value of 15 mA.
Isolation:
- The device provides a high isolation voltage of up to 3750 Vrms for 1 minute at 50/60 Hz. Ensure proper insulation and handling to prevent electrical hazards.
Temperature:
- Operate the device within the temperature range of -40掳C to 105掳C to ensure reliable performance.
- Store the device in an environment between -55掳C and 125掳C to prevent degradation.
Mounting and Handling:
- Handle the device with care to avoid mechanical stress or damage.
- Follow recommended soldering profiles to prevent thermal damage during assembly.
Testing:
- Before finalizing the design, conduct thorough testing under all expected operating conditions to ensure the device meets performance requirements.
Compliance:
- Ensure the device complies with all relevant safety and regulatory standards for the intended application.
View more about HCPL-0611-000E on main site