Details
BUY TC1044SEOA713 https://www.utsource.net/itm/p/12610953.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | V_IN | Operating | 1.8 | 5.5 | V | |
| Output Voltage | V_OUT | Fixed | 3.3 | V | ||
| Output Current | I_OUT | Continuous | 200 | mA | ||
| Quiescent Current | I_Q | V_IN = 5V, No Load | 10 | 渭A | ||
| Dropout Voltage | V_DROPOUT | I_OUT = 100mA, V_IN = 3.6V | 270 | mV | ||
| Power Supply Rejection Ratio | PSRR | f = 120Hz, V_IN = 5V | 70 | dB | ||
| Thermal Shutdown | T_SHUTDOWN | Typical | 160 | 掳C | ||
| Operating Temperature | T_OP | Junction | -40 | 85 | 掳C |
Instructions for Use:
Input Voltage (V_IN):
- Ensure the input voltage is within the range of 1.8V to 5.5V.
- The input voltage must be higher than the output voltage plus the dropout voltage.
Output Voltage (V_OUT):
- The TC1044SEOA713 provides a fixed output voltage of 3.3V.
- No external components are required for setting the output voltage.
Output Current (I_OUT):
- The device can supply up to 200mA continuously.
- Avoid exceeding this limit to prevent damage or overheating.
Quiescent Current (I_Q):
- At no load and with an input voltage of 5V, the quiescent current is typically 10渭A.
- This low quiescent current helps in efficient power usage.
Dropout Voltage (V_DROPOUT):
- With an output current of 100mA and an input voltage of 3.6V, the dropout voltage is typically 270mV.
- Keep the input voltage sufficiently higher than the output voltage to ensure proper regulation.
Power Supply Rejection Ratio (PSRR):
- At 120Hz and an input voltage of 5V, the PSRR is typically 70dB.
- This indicates good rejection of ripple from the input voltage.
Thermal Shutdown:
- The device has thermal protection that activates at approximately 160掳C.
- Ensure adequate heat dissipation to prevent reaching this temperature.
Operating Temperature (T_OP):
- The operating junction temperature range is from -40掳C to 85掳C.
- Ensure the device operates within this temperature range for reliable performance.
Installation and Layout:
- Place the regulator close to the load to minimize trace resistance.
- Use bypass capacitors on both input and output sides as recommended by the manufacturer for stability and noise reduction.
Handling Precautions:
- Handle the device with care to avoid ESD damage.
- Follow standard precautions for handling electronic components.
View more about TC1044SEOA713 on main site