Details
BUY 93C46CB6 https://www.utsource.net/itm/p/12610976.html
| Parameter | Description | Value |
|---|---|---|
| Device Type | Serial EEPROM | 93C46CB6 |
| Organization | Organization of Memory | 512 x 8 bits |
| Supply Voltage (Vcc) | Operating Supply Voltage | 2.5V to 5.5V |
| Standby Current | Current Consumption in Standby Mode | 1 渭A (max) |
| Active Current | Current Consumption in Active Mode | 5 mA (max) |
| Operating Temperature | Temperature Range for Normal Operation | -40掳C to +85掳C |
| Write Time | Maximum Time Required for a Write Operation | 5 ms (max) |
| Data Retention | Minimum Guaranteed Data Retention Time | 10 years |
| Write Cycles | Number of Write/Erase Cycles per Memory Location | 1,000,000 |
| Package | Package Type | SOIC-8 |
| Pin Configuration | Pin Configuration | Vcc, GND, SI, SO, SCK, CS, /WP, Vpp (pin 8 NC) |
| Communication Protocol | Serial Communication Interface | SPI |
Instructions for Use
Power Supply:
- Connect the Vcc pin to a power supply within the range of 2.5V to 5.5V.
- Connect the GND pin to the ground.
Pin Configuration:
- SI (Serial Input): Data input pin.
- SO (Serial Output): Data output pin.
- SCK (Serial Clock): Clock input pin.
- CS (Chip Select): Active low chip select pin.
- /WP (Write Protect): Active low write protect pin. Set high to enable writing.
- Vpp (pin 8 NC): Not connected. Leave this pin unconnected.
Communication:
- The 93C46CB6 uses the SPI protocol for communication.
- Ensure that the SCK, SI, SO, and CS pins are properly connected to the corresponding pins on the microcontroller or host device.
Write Operation:
- To write data, first ensure that the /WP pin is set high to disable write protection.
- Assert the CS pin low to select the device.
- Send the appropriate write command followed by the address and data.
- Deassert the CS pin high to complete the write operation.
- Wait for the write time (5 ms max) before performing another operation.
Read Operation:
- Assert the CS pin low to select the device.
- Send the appropriate read command followed by the address.
- The device will output the data on the SO pin.
- Deassert the CS pin high to complete the read operation.
Standby Mode:
- To enter standby mode, deassert the CS pin high.
- The device will consume minimal current (1 渭A max).
Data Retention:
- The device guarantees data retention for at least 10 years under normal operating conditions.
Handling Precautions:
- Handle the device with care to avoid static discharge.
- Ensure that all connections are secure and within the specified voltage ranges to prevent damage.
For more detailed information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about 93C46CB6 on main site