Details
BUY 2SD716 https://www.utsource.net/itm/p/12611006.html
| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Collector-Emitter Voltage | VCE | - | - | 80 | V | |
| Collector-Base Voltage | VCB | - | - | 80 | V | |
| Emitter-Base Voltage | VEB | - | - | 5 | V | Reverse |
| Collector Current | IC | - | 1.5 | 3 | A | Continuous |
| Collector Current (Pulse) | IC(P) | - | 3 | 6 | A | Pulse Width ≤ 300 μs |
| Power Dissipation | PT | - | - | 65 | W | TA = 25°C |
| Operating Temperature | TOP | -55 | - | 150 | °C | |
| Storage Temperature | TS | -65 | - | 150 | °C | |
| Transition Frequency | fT | - | 400 | 600 | MHz | |
| Base-Emitter Saturation Voltage | VBE(sat) | 1.2 | 1.8 | 2.2 | V | IC = 1.5 A, IB = 150 mA |
| Collector-Emitter Saturation Voltage | VCE(sat) | 0.7 | 1.2 | 1.5 | V | IC = 1.5 A, IB = 150 mA |
| Current Gain (DC) | hFE | 20 | 70 | 150 | - | IC = 1.5 A, VCE = 5 V |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use recommended mounting torque for screws to avoid damage to the transistor.
Biasing:
- Ensure that the base-emitter voltage (VBE) is within the specified range to prevent excessive current and potential damage.
- Use appropriate biasing circuits to maintain stable operation over temperature variations.
Current Limiting:
- Implement current limiting resistors or other protection mechanisms to prevent the collector current from exceeding the maximum ratings.
- For pulse applications, ensure that the pulse width and frequency do not exceed the specified limits.
Thermal Management:
- Monitor the operating temperature and use thermal management techniques such as heatsinks or cooling fans if necessary.
- Avoid operating the device at temperatures beyond the specified range to prevent thermal runaway.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Handle with care to avoid mechanical stress or damage to the leads.
Testing:
- Use appropriate test equipment and procedures to verify the performance parameters of the device.
- Follow safety guidelines when handling high-voltage and high-current circuits.
Environmental Considerations:
- The device is sensitive to electrostatic discharge (ESD). Use ESD protection measures during handling and installation.
- Comply with all environmental regulations regarding disposal and recycling of electronic components.
View more about 2SD716 on main site