UCC3802N

UCC3802N


Specifications
Details

BUY UCC3802N https://www.utsource.net/itm/p/12611021.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 7.5 30 V Operating supply voltage range
Quiescent Current IQ 1.5 mA Supply current when not switching
Input High Level VIH 2.4 Vcc V Minimum input voltage for logic high
Input Low Level VIL 0 0.8 V Maximum input voltage for logic low
Output High Voltage VOH Vcc-1 Vcc-0.5 V Output voltage level for logic high (at IOL)
Output Low Voltage VOL 0 0.4 V Output voltage level for logic low (at IOH)
Propagation Delay tpd 160 ns Delay time from input to output
Power Dissipation PD 750 mW Maximum power dissipation
Operating Temperature Topr -40 85 掳C Operating temperature range
Storage Temperature Tstg -65 150 掳C Storage temperature range

Instructions for UCC3802N

  1. Power Supply Connection:

    • Connect the supply voltage (Vcc) within the specified range of 7.5V to 30V.
    • Ensure the quiescent current does not exceed 1.5mA under normal operating conditions.
  2. Input Signal Levels:

    • Apply input signals where logic high is above 2.4V and logic low is below 0.8V.
    • Ensure the input voltage does not exceed the supply voltage (Vcc).
  3. Output Configuration:

    • For proper operation, ensure the output high voltage (VOH) is at least Vcc-1V and output low voltage (VOL) does not exceed 0.4V.
    • Check the load requirements to ensure the output can drive the connected devices without exceeding maximum ratings.
  4. Timing Considerations:

    • Account for a propagation delay of approximately 160ns in timing-sensitive applications.
  5. Thermal Management:

    • Operate the device within the temperature range of -40掳C to 85掳C for optimal performance.
    • Store the device between -65掳C and 150掳C when not in use.
  6. Power Dissipation:

    • Keep the power dissipation below 750mW to avoid overheating and potential damage to the component.
  7. Handling Precautions:

    • Use appropriate ESD protection when handling the UCC3802N to prevent damage from static electricity.
(For reference only)

View more about UCC3802N on main site