AWL5905P8

AWL5905P8


Specifications
SKU
12611025
Details

BUY AWL5905P8 https://www.utsource.net/itm/p/12611025.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 5.0 5.5 V Operating supply voltage
Input Current Iin - - 100 mA Maximum input current
Output Current Iout 0 - 100 mA Maximum output current
Operating Temp. Topr -40 - 85 °C Operating temperature range
Storage Temp. Tstg -65 - 150 °C Storage temperature range
Quiescent Current Iq - 0.1 - mA Quiescent current at no load
Dropout Voltage Vdo - 0.2 - V Dropout voltage at full load
Load Regulation ΔVout - 0.5 - % Change in output voltage with load
Line Regulation ΔVout - 0.2 - % Change in output voltage with input voltage
Ripple Rejection RR - 70 - dB Power supply rejection ratio at 100 kHz

Instructions for Using AWL5905P8

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the specified range of 4.5V to 5.5V.
    • Use a stable power source to avoid fluctuations that could affect performance.
  2. Input and Output Connections:

    • Connect the input (Vin) to the positive terminal of the power supply.
    • Connect the output (Vout) to the load or circuit requiring regulated power.
    • Ground (GND) must be connected to the common ground of the system.
  3. Current Handling:

    • Do not exceed the maximum input current (Iin) of 100mA.
    • The output current (Iout) should not exceed 100mA to prevent damage to the device.
  4. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 85°C for optimal performance.
    • Store the device in a temperature range of -65°C to 150°C.
  5. Quiescent Current:

    • The quiescent current (Iq) is typically 0.1mA when there is no load on the output. This is important for low-power applications.
  6. Dropout Voltage:

    • The dropout voltage (Vdo) is typically 0.2V at full load. Ensure the input voltage is at least 0.2V higher than the desired output voltage.
  7. Regulation:

    • The load regulation (ΔVout) is typically 0.5%, meaning the output voltage will change by 0.5% with changes in load.
    • The line regulation (ΔVout) is typically 0.2%, indicating the output voltage will change by 0.2% with changes in input voltage.
  8. Ripple Rejection:

    • The ripple rejection (RR) is typically 70dB at 100 kHz, which helps in filtering out noise from the power supply.
  9. Capacitors:

    • Use appropriate input and output capacitors to stabilize the voltage and reduce ripple. Typical values are 10μF for input and 10μF for output.
  10. PCB Layout:

    • Ensure proper PCB layout with short traces between the input and output capacitors and the device to minimize noise and improve stability.

By following these guidelines, you can ensure reliable and efficient operation of the AWL5905P8.

(For reference only)